Use charger for charging a LEAD-ACID (lead acid, sealed lead acid, gel cell, and AGM) battery only.  It is 

not intended to supply power to a low voltage electrical system other than in a starter-motor application.   

Do not use battery charger for charging dry-cell batteries that are commonly used with home appliances.  

These dry cell batteries may explode, causing personal injury and damage to property.  
  

NEVER charge a frozen battery.  

  

PREPARING TO CHARGE  

If it is necessary to remove the battery or batteries to charge, always remove grounded terminal from 

battery first.  Make sure all accessories are off, so as not to cause battery arcing.  
  

Be sure the area around any battery is well ventilated while batteries are being charged.  On occasion, 

“gas fumes” may be present during charging and can be forcefully blown away by using a piece of 
cardboard or other nonmetallic material as a fan.  Proper ventilation is always recommended in the 
charging area.  
  

Clean all of the battery terminals.  Be careful to keep corrosion from coming into contact with eyes.  

  

Add distilled water in each cell (wet cell batteries) until battery acid reaches level specified by battery 

manufacturer.  This helps purge excessive gas from cells.  Do not overfill.  For a battery without cell caps, 
carefully follow manufacturer’s recharging instructions.  
  

Study all battery manufacturers’ specific precautions such as removing or not removing cell caps while 

charging and recommended rates of charge.  
  

Extension cords should be industrial grade/heavy duty UL approved and grounded.  Check extension cord 

before use for damage, bent prongs and cuts.  Replace if damaged.  
  

Always make your extension cord connection on the charger side first.  After connecting the extension 

cord to the charger, proceed to plug the extension cord into a 120VAC GFCI protected (Ground Fault 
Circuit Interrupt) A/C outlet.   The unit will operate with a VAC input range of 90VAC-264VAC.  
  

Always remove the extension cord from the A/C outlet first when charging is completed followed by 

unplugging the charger.  
  

PRODUCT SUMMARY  

General Operation: 

 

Use the following guidelines in this manual to install your fully automatic PCS battery charging system.    

  

Assure that the area around your charger and batteries is properly ventilated.  Connect your extension 

cord with no A/C power present to the battery charger and proceed to plug your extension cord in at a 
nearby A/C outlet.  
  

Once you plug in your PCS battery charging system, your batteries will be simultaneously and 

independently charged to 100%.  Unlike systems that utilize one large charger to attempt to charge 
multiple batteries, your system utilizes a totally independent battery charger for each battery.  Each 
charging bank will remain in a “float” stage once the battery is charged and then monitor and/or maintain 
the battery indefinitely.  
  

We recommend that you leave your system plugged in.  This will reduce sulfation on the lead plates of the 

batteries and allow your PCS charging system to keep your batteries fully maintained and ready to 
perform at their best.  
  

Independent Charging Bank Indications  

When your battery charging system is activated, each bank provides charging information utilizing 1 red  

Содержание DUAL PRO Industrial Series

Страница 1: ...rgers shown below IS1 One 6 amp output IS2 Two 6 amp outputs IS3 Three 6 amp outputs For additional information please call our Technical Support Group 615 471 5300 081512 PRO CHARGING SYSTEMS LLC 155...

Страница 2: ...built tough to withstand intense vibration extreme temperature variations and submersion without damaging the unit Our systems use temperature compensation in order to fully charge a battery in hot o...

Страница 3: ...uctions exactly 2 To reduce risk of battery explosion follow these instructions and those published by the battery manufacturer and by the manufacturer of any equipment you intend to use in the vicini...

Страница 4: ...l grade heavy duty UL approved and grounded Check extension cord before use for damage bent prongs and cuts Replace if damaged Always make your extension cord connection on the charger side first Afte...

Страница 5: ...stems are designed to be permanently installed in a well ventilated area and have no mounting restrictions Do not make any electrical connections to the power supply AC or to a battery DC until the in...

Страница 6: ...and the charger Each charge cable assembly is equipped with a temperature sensor located at the junction of each set of ring terminals Attempts to shorten the cables could partially disable the charge...

Страница 7: ...ith the AC power supply cord unplugged check the ring terminals for correct polarity Red to positive or and Black to negative or Also check for corrosion free secure connections to the batteries Check...

Страница 8: ...ling or handling charges prepaid to the manufacturer or its authorized representative This limited warranty is void if the product is misused improperly maintained handled carelessly or incorrectly op...

Страница 9: ...9 Below are some of our other options in chargers and battery accessories Call our technical support group for more detailed information or visit our web site www dualpro com...

Отзывы: