CHARGING INDICATIONS 

When your battery charging system is activated, the battery status indicator provides charging information utilizing five red 
LED indicators and one green LED indicator. 

 

Battery Type Indicators 

Two amber LED indicators are provided in order to display what type of battery the 
charger has been programmed to charge.  

NOTE:

 For information on reconfiguring 

the battery type, please contact technical support (800.742.2740). 

 
Battery System Percent Charged Indicators  

Four LED indicators are provided in order to display the progress of the charge cycle 
in percentage of charge.   

Indications are as follows: 
 
1

ST

 Amber LED . . . .  . . . . . . .  Illuminated configured for Wet Cell and 

AGM*

 batteries 

2

ND

 Amber LED . . . . . . . . . . . . . Illuminated configured for Gel Cell batteries 

1

ST 

 RED LED . . . . . . . . . . . . .   Charging - Initial Charging Up To 30%  

2

ND

 & 3

RD

 RED LEDS  . . . . . . .   Charging - 60% Complete  

1

ST

, 2

ND

 & 3

RD

 RED LEDS. . . .  Charging - 90% Complete  

BLINKING GREEN LED  . . . .   Finishing Stage (Note: Battery Type Indicator will also blink during this stage)  
STEADY GREEN LED  . . . . . .  Charge Complete –Float/Maintenance Mode-On for 5 minutes and off for 60 minutes 
 

*We normally recommend our STANDARD Delta Volt profile for AGM Batteries.  There are some cases where 
particular AGM batteries are manufactured to different specifications and may need a special profile with a much 
lower finish voltage limitation.  In these cases we will do our best to accommodate your unique need. 

 
The green LED is illuminated whenever the charge cycle has terminated and the internal circuitry has determined the 
batteries to be fully charged. The green LED will blink during the finishing stage of the charge cycle.  After the completion of 
the charge cycle, the green LED will remain on steady during the float-maintenance stage.  

During this final stage current 

is only flowing to the battery system for 5 minutes and then current will stop completely for 60 minutes.   
 
Your system provides an equalization stage every 30 days while plugged in.  If the charger is normally disconnected 
from A/C after completing charge, equalization can be accomplished by plugging back into A/C whenever this stage 
is desired. Battery manufacturers recommend that equalization is done once a month in order to further reduce 
sulfation on the lead plates of a battery, which helps promote longer battery life.  Note:  During this process the 
LEDs will go through their normal routine(Red LEDs counting up for % of charge along with the illuminated  Red 
LED Battery Type) and then the Green LED and Red Battery Type LED will blink) until the unit returns to the 
maintenance mode and a steady Green LED and steady Red Battery Type LED. (Not applicable to Gel Profile) 

 
TROUBLESHOOTING  

 
PROBLEM: No LED indicators illuminated on battery status indicator. 

Solution Sequence: 
1. Confirm that current is being delivered to the charger. Use a meter or test light to check the AC power supply from its 
source through all connecting points up to the charger. 
2. Check that the AC circuit breaker (on front of the unit) is depressed. 
3. Call technical support for further assistance (800.742.2740). 

 
PROBLEM: The charge status indicator changes rapidly back and forth from red to green or the green LED will not 
illuminate after excessive charging time (24 hours or more). 

Solution Sequence: 
1. Disconnect AC power from the charging system. This indication may signify a possible battery problem. 
2. Call technical support for further assistance (800.742.2740). 

 
PROBLEM: A green LED was illuminated before disconnecting the power from the charger, but upon reconnection, 
red LEDs appear and remain on. 

This is the normal operating procedure for the system. It indicates that a reanalysis of the battery status was initiated and 
after a series of steps the green LED will illuminate. 

 

 

Содержание 1250OB

Страница 1: ...4836OB _______________________________________ 021313 IMPORTANT NOTICE Please save and read these safety operating and installation instructions before installing or applying AC power to your Pro Charging Systems PCS charger Contact technical support at PCS with any product installation or service questions 800 742 2740 Pro Charging Systems LLC LaVergne TN 37086 3539 ...

Страница 2: ...ty and operating instructions for future reference CONCERVER CES INSTRUCTIONS CE MANUEL CONTIENT DES INSTRUCTIONS IMPORTANTES CONCERNANT LA SÉCURITÉ ET LE FONCTIONNEMENT Understand and relate the Hazard Levels and Signal Words utilized in this manual with the following definitions This symbol means Immediate hazards which will result in severe personal injury or death This symbol means Hazards or ...

Страница 3: ...ose to rain Keep work area well lit 8 Do not overreach Keep proper footing and balance at all times Do not reach over or across electrical cables or frames 9 Avoid electrical shock To reduce risk of electrical shock unplug charger from outlet before attempting any maintenance or cleaning 10 Do not operate charger with damaged electrical cord or plug To reduce risk of damage to the electrical plug ...

Страница 4: ...anufacturers specific precautions such as removing or not removing cell caps while charging and recommended rates of charge When using an extension cord make sure that pins on plug of extension cord are the same number size and shape as those of the charger s plug that extension cord meets UL Underwriters Laboratories Inc acceptance that wire size is large enough for AC ampere rating of charger Al...

Страница 5: ...order to reduce the risk of fire use only on circuits provided with 30Amperes Branch Circuit Protection in accordance with the National Electrical Code ANSI NFPA 70 Study all battery manufacturers specific precautions such as removing or not removing cell caps while charging and recommended rates of charge Prendre connaissance des measures de précaution spécifiés par le fabricant de la batterie p ...

Страница 6: ...t is only flowing to the battery system for 5 minutes and then current will stop completely for 60 minutes Your system provides an equalization stage every 30 days while plugged in If the charger is normally disconnected from A C after completing charge equalization can be accomplished by plugging back into A C whenever this stage is desired Battery manufacturers recommend that equalization is don...

Страница 7: ...Charging Systems LLC PCS makes this Limited Warranty only to the original retail purchaser PCS warrants this battery charger for three years unless the serial number ends with a suffix of RM or CR from the date of retail purchase against defective materials and or workmanship RM suffix refers to Restricted Markets such as Rental applications and Heavy Industrial applications and designates the war...

Страница 8: ...8 ...

Отзывы: