CHARGING INDICATIONS
When your battery charging system is activated, the battery status indicator provides charging information utilizing five red
LED indicators and one green LED indicator.
Battery Type Indicators
Two amber LED indicators are provided in order to display what type of battery the
charger has been programmed to charge.
NOTE:
For information on reconfiguring
the battery type, please contact technical support (800.742.2740).
Battery System Percent Charged Indicators
Four LED indicators are provided in order to display the progress of the charge cycle
in percentage of charge.
Indications are as follows:
1
ST
Amber LED . . . . . . . . . . . Illuminated configured for Wet Cell and
AGM*
batteries
2
ND
Amber LED . . . . . . . . . . . . . Illuminated configured for Gel Cell batteries
1
ST
RED LED . . . . . . . . . . . . . Charging - Initial Charging Up To 30%
2
ND
& 3
RD
RED LEDS . . . . . . . Charging - 60% Complete
1
ST
, 2
ND
& 3
RD
RED LEDS. . . . Charging - 90% Complete
BLINKING GREEN LED . . . . Finishing Stage (Note: Battery Type Indicator will also blink during this stage)
STEADY GREEN LED . . . . . . Charge Complete –Float/Maintenance Mode-On for 5 minutes and off for 60 minutes
*We normally recommend our STANDARD Delta Volt profile for AGM Batteries. There are some cases where
particular AGM batteries are manufactured to different specifications and may need a special profile with a much
lower finish voltage limitation. In these cases we will do our best to accommodate your unique need.
The green LED is illuminated whenever the charge cycle has terminated and the internal circuitry has determined the
batteries to be fully charged. The green LED will blink during the finishing stage of the charge cycle. After the completion of
the charge cycle, the green LED will remain on steady during the float-maintenance stage.
During this final stage current
is only flowing to the battery system for 5 minutes and then current will stop completely for 60 minutes.
Your system provides an equalization stage every 30 days while plugged in. If the charger is normally disconnected
from A/C after completing charge, equalization can be accomplished by plugging back into A/C whenever this stage
is desired. Battery manufacturers recommend that equalization is done once a month in order to further reduce
sulfation on the lead plates of a battery, which helps promote longer battery life. Note: During this process the
LEDs will go through their normal routine(Red LEDs counting up for % of charge along with the illuminated Red
LED Battery Type) and then the Green LED and Red Battery Type LED will blink) until the unit returns to the
maintenance mode and a steady Green LED and steady Red Battery Type LED. (Not applicable to Gel Profile)
TROUBLESHOOTING
PROBLEM: No LED indicators illuminated on battery status indicator.
Solution Sequence:
1. Confirm that current is being delivered to the charger. Use a meter or test light to check the AC power supply from its
source through all connecting points up to the charger.
2. Check that the AC circuit breaker (on front of the unit) is depressed.
3. Call technical support for further assistance (800.742.2740).
PROBLEM: The charge status indicator changes rapidly back and forth from red to green or the green LED will not
illuminate after excessive charging time (24 hours or more).
Solution Sequence:
1. Disconnect AC power from the charging system. This indication may signify a possible battery problem.
2. Call technical support for further assistance (800.742.2740).
PROBLEM: A green LED was illuminated before disconnecting the power from the charger, but upon reconnection,
red LEDs appear and remain on.
This is the normal operating procedure for the system. It indicates that a reanalysis of the battery status was initiated and
after a series of steps the green LED will illuminate.