LINK
INPUT
LINK
INPUT
LINK
INPUT
LINK
INPUT
LINK
INPUT
» SICUREZZA
INTERCOM 200 series »
IC200B
User Manual
• Read all documentation before using your equipment. Retain all documentation for further reference. • Do not use this apparatus near water. • Clean only with a dry cloth.
• Mains voltage must be correct and the same as that printed on the rear of the unit. • Always operate the unit with the AC ground wire connected to the electrical system
ground. • Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way.
WARNING! Please read the instruction carefully which include important information about the installation and usage.
TO PREVENT ELECTRIC SHOCK DO NOT REMOVE TOP OR BOTTOM COVERS. DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE
NO USER SERVICEABLE PARTS INSIDE - REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
GB
The unit is compatible with other manufacturers systems. Compatibility data sheet may be supplied on request.
Compatibility
FP- 10 /05/09 - Rev001 - 05/09 ©2009 Music & Lights s.r.l. - Italy - www.proaudioline.it
Connections and controls
The female 3 pin XLR3 connector INPUT (1) must be connected to the power supply unit, to the master station or to the
male 3 pin XLR3 connector LINK (2) of another remote station. The headset must be connected to the 4 pin male XLR4
connector (3) . The stations are designed for use with low impedance (600
Ω
nominal) unbalanced dynamic micro-
phones and high impedance (100 ÷ 1000
Ω
) unbalanced headphones.
For connection to the remote stations, it’s possible
to use standard microphone cables (2 conductors +
screen) (9) , in case of very long connections we strong-
ly suggest to use a 3 conductors + screen cable, having
at least 0.18 mm2 conductors, using the third conduc-
tor to connect the XLR connector’s body (frame) (10).
Max cable length may be more than 500 m, if cables
with large conductors and good screening are used.
General
Line impedance
220 Ω (audio) – 4700 Ω (dc)
Nominal line level
-17 dBm
Max line level
+4 dBm
Supply voltage range
15÷30 V dc, 28 V dc nominal, 36 V dc max
Current drain (at 28 Vdc)
18 mA typ. when operating, 50 mA max when calling
Station input impedance
18 kΩ (equivalent, bridging the intercom line)
Microphone preamplifier
Frequency response
150 Hz ÷ 13 kHz (contoured for a better intelligibility)
Imput impedance
1 kΩ (to be used with 200 Ω ÷ 1 kΩ dynamic microphones)
Gain
29 dB
Maximum input level
-30dBm
Headphones amplifier
Frequency response
150 Hz ÷ 18 kHz (± 2 dB)
Gain
+40 dB
Maximum output level
+20 dBm (with 1 kΩ load)
Load impedance
200Ω ÷ 1000 Ω headphones, 32 Ω minimum
SIDE TONE adjustment range
± 20 dB, - 60 dB minimum at center position
Call circuit
Nominal call voltage
+ 12 V dc on audio line
Call detector sensitivity
+ 2 V d.c.
Dimenasions, weight and accessories
Dimensions and weight
90 x 42 x 108 mm (l x h x d) (excluding the belt clip). 370 g
Supplied accessories
Nylon belt clip (removable for table-top mounting)
Technical specifications
ICH01 o ICH02
headset
1
1
2
2
3
3
The MIC on/off switch (4) allows the microphone to be switched on and off. It is suggested to switch the microphone off, if not used, to reduce unwanted noise in the intercom
line. The green LED is lighted when the microphone is on. The rotary VOLUME control (6) adjust headphones listening volume. The screwdriver adjustable SIDE TONE trimmer
(7) adjust the level of the local microphone returned to the station’ s headphones. This control does not affect the microphone signal sent to other stations. In the center position
the microphone level (return) is kept to a minimum, but if the control is rotated clockwise or counterclockwise the microphone signal is returned to the headphones amplifier
with adjustable level and phase. Some users prefer to hear their own microphone’s signal for being sure that it’s operating. By pressing the CALL button (4) a call signal is sent to
all the stations connected to the same intercom line. The CALL lamp on these station flashes. The BUZZER switch (5), when set to the LO and HI position, enables the acoustic call
signaling, and adjusts the buzzer volume, to low (LO) or high (HI) level. If the buzzer is on, the yellow LED is lighted. In the OFF switch position, the buzzer is disabled.
4
5
6
7
8
2
1
3
1
2
3
4
XLR 4P F
( soldering side )
MIC.
MIC.
PHONES
PHONES
9
2 cond screen wired cable.
( Microphonic standard cable ).
10
3 cond screen wired cable.
( Suggested for very long connections ).
XLR 3P M
XLR 3P F
2 4 1
3
1 4 2
3
(1) GROUND (screen)
(2) SUPPLY
(4) FRAME
(3) AUDIO
2
1
3
1
2
3
(1) GROUND (screen)
(2) SUPPLY
(3) AUDIO
XLR 3P M
XLR 3P F
For further information, please contact our Service Center: tel. +39 0771 72190 fax +39 0771 721955 - [email protected]