background image

The display range of temperature
The control range of temperature
Load rating
Display accuracy
Swing (cycle rate or differential)

Power source

Operating ambient
Operating humidity
Dimensions of thermostat

41ºF to 95ºF (5ºC to 35ºC)
44ºF to 90ºF (7ºC to 32ºC)
1 amp per terminal, 1.5 amp maximum all terminals combined
± 1ºF
Heating is adjustable from 0.4ºF to 2.0ºF 
Cooling is adjustable from 0.4ºF to 2.0ºF 
18 to 30 VAC, NEC Class II, 50/60 Hz for hardwire (common wire)
Battery power from 2 AA Alkaline Energizer batteries
32ºF to +105ºF (0º to +41ºC)
90% non-condensing maximum
4.7”W x 4.4”H x 1.1”D

13

SPECIFICATIONS & CONTACT INFORMATION

Specifications

Pro1 IAQ Inc.

1111 S. Glenstone

Suite 2-100

Springfield, MO 65804

Toll-free: 1-888-Pro1iaq (776-1427)

Toll Number (Outside the USA):  330-821-3600

Web: http://www.pro1iaq.com

Hours of Operation: Monday - Friday 9 AM - 6 PM Eastern

Содержание TRUE COMFORT IIII

Страница 1: ...Battery Power Hardwire Common Wire Hardwire Common Wire with Battery Backup Power Type 1 n o i t p i r c s e D Gas or Oil Heat Electric Furnace Heat Pump No Aux or Emergency Heat Heat Pump with Aux o...

Страница 2: ...are in direct sunlight With an outside wall behind the thermostat In areas that do not require conditioning Where there are dead spots or drafts in corners or behind doors Where there might be conceal...

Страница 3: ...splayed when thermostat program is permanently overridden 1 will appear in the display when second stage of heat or cool is on 2 will appear for third stage of heat System operation indicators The COO...

Страница 4: ...ducts are mercury free However if the product you are replacing contains mercury dispose of it properly Your local waste management authority can give you instructions on recycling and proper disposal...

Страница 5: ...rgized in cooling Fan relay Emergency heat relay First stage of heat cool Second stage of cool second stage of heat Auxiliary heat relay third stage of heat This thermostat is shipped from the factory...

Страница 6: ...es and a larger swing setting will cause fewer cycles Keypad lockout allows you to configure the thermostat so that none or some of the keys do not function The heating swing setting is adjustable fro...

Страница 7: ...2 or 24 Hour Clock Use the or key to turn on or off ON This feature turns your system on before the WAKE programming time to ensure the enviroment is at the WAKE setpoint when the WAKE time period beg...

Страница 8: ...one character to another See note below on operation If selected on you will see the input screen after pressing next step Note If Contractor Call Number is selected ON your phone number will show in...

Страница 9: ...LATION Mount Thermostat Align the 4 tabs on the subbase with corresponding slots on the back of the thermostat then push gently until the thermostat snaps in place On the back of the thermostat insert...

Страница 10: ...ng Use the or key to select the current day of the week Press NEXT STEP The current hour is flashing Use the or key to select the current hour When using 12 hour time make sure the correct a m or p m...

Страница 11: ...ime period Note If you want the fan to run continuously during this time period select ON with the FAN key Press NEXT STEP The setpoint temperature is flashing Use the or key to make your setpoint sel...

Страница 12: ...STEP Repeat steps 4 thru 7 for Monday LEAVE time period for Monday RETURN time period and for Monday SLEEP time period PROGRAMMING THE THERMOSTAT 12 1 2 3 4 5 6 7 8 Monday Repeat steps 4 thru 7 for th...

Страница 13: ...adjustable from 0 4 F to 2 0 F Cooling is adjustable from 0 4 F to 2 0 F 18 to 30 VAC NEC Class II 50 60 Hz for hardwire common wire Battery power from 2 AA Alkaline Energizer batteries 32 F to 105 F...

Отзывы: