1.5

 

Contraindications/Limitations 

There are no known “contraindications” associated with the usage of the 

CP hoist and its accessories, provided they are used as 

per manufacturer’s recommendations and guidelines.

 However, it is recommended that a client specific assessment is 

completed by a trained and knowledgeable health care professional to determine the method of transfer. 
 
Prism does not recommend a required number of care givers for the use of our products. This information and recommendation 
can only be provided after a thorough personalized, case specific assessment, as there are many factors that can influence these 
decisions. 

1.6

 

Intended Use 

For internal use only. 
 
This manual covers the CP130 and CP200 Ceiling Track Hoists, along with all variants for various track types.  

 
All models of CP130 found in Table 1 have a Safe Working Load (SWL) of 130kg.  
All models of CP200 found in Table 1 have a Safe Working Load (SWL) of 200kg. 
 
With a safe working load of 130kg / 200kg, the CP Hoist is a raising and 
lowering aid used to transfer people safely. The Hoist makes it possible to 
move mobility impaired individuals with minimal strain or risk to the 
caregiver, while providing complete safety, dignity and comfort for the 
person being moved. 
 
The easy to use hoist is designed to be operated by both professional health 
care workers and home health care workers who may not have a specific 
range of skills in health care. Typical home care users may include, but is not 
limited to, teachers, medics, paramedics, carers, family and friends. Focusing 
on the dignity and wellbeing of the person being moved, the simple to use 
hoist maximises the amount of care provided to the person.

 

 

 
The CP Hoist is a ceiling track hoist and should only be used whilst on the ceiling track. It has the ability to raise up an individual 
from one location, such as a bed, move the individual along the track to another location and finally lower the individual, such as 
into a chair or a bath. 
 
The CP is intended to be used with Prism/Mackworth/Care-ability slings, a Prism clipped carry bar and the Prism ceiling track 
system or Free Standing Gantry. Together these three items make up the system. Please refer to any user guides supplied with 
the sling and track system and reference them while reviewing this manual.  
 

A risk assessment must be performed before using any other manufactured sling, carry bar or ceiling track to ensure 

safe

 use can be established. 

The device is used under instruction and the operation of the aid is undertaken by a trained carer. 

 
The carry bar is manufactured by Prism, associated for use with this device, incorporates three fixing point options at either end 
of carry bar, with a safety retaining clip on the outer hook. The fixing can be derived by the user, by means of a simple 
connection loop, made by the sling, to the carry bar. This connection system is used throughout the industry in various designs 
but all acts as the means to hold the sling and user in place through operation of the device whilst in use. 
 
The sling is a specially designed fabric accessory that attaches to the hoist by means of a carry bar and strap system, and holds 
an individual while the hoist or transfer takes place. The sling is supplied separately from the hoist at the initial time of purchase.  
 
The track, also supplied separately from the hoist at the time of purchase, is the means to operate the hoist in a defined safe 

route, enabling the person different uses around the “travel” of the hoist.

 

If additional accessories have been supplied with the hoist, refer to the instructions included with those items. 

Figure 1

 

Содержание 108601

Страница 1: ...Doc No 999016 Revision of document G Revision Date 08 12 2021 CP Ceiling Track Hoist User Manual...

Страница 2: ...12 3 0 Installation 13 4 0 Type BF Applied parts 14 5 0 Frequently Used Functions 14 5 1 Carry Bar 14 5 2 Slings 15 5 3 Connecting the Handset to the Hoist 23 6 0 Hoist Operation 24 6 1 Turning the Ho...

Страница 3: ...1 8 2 Shipping and storage conditions 31 9 0 Disposal 31 10 0 Fault Finding 32 10 1 LED Display 33 11 0 General Inspection Maintenance and Cleaning 34 11 1 Service 34 11 2 Inspection 34 Lift Tape Caut...

Страница 4: ...CP130 108619 White Carry Bar Type 2 CP130 108603 Black Carry Bar Type 3 CP130 108620 White Carry Bar Type 3 CP130 108604 Black Carry Bar Type 4 CP130 108621 White Carry Bar Type 4 CP130 108605 Black C...

Страница 5: ...anual may result in injury to the operator and or client and or damage to the Hoist or related components Contents of this manual are subject to change without prior notice Do not attempt to use this...

Страница 6: ...which protection against electric shock does not rely on basic insulation only Safe Working Load represents the maximum load rated for safe operation Manufacturer Date of manufacture Packaging indicat...

Страница 7: ...oist is a ceiling track hoist and should only be used whilst on the ceiling track It has the ability to raise up an individual from one location such as a bed move the individual along the track to an...

Страница 8: ...e CP hoist should be inspected and maintained on a regular basis See section General Inspection Maintenance and Cleaning within this user manual Any accessories used with the CP including track and sl...

Страница 9: ...se report it to the manufacturer and to your national authority Electric Shock Do not insert any objects into the hoist case or battery charging station because of potential risk of electric shock To...

Страница 10: ...he system as the manufacturer s adapter has been assessed and complies with the EMC requirements This product manufactured by Prism has been designed manufactured and tested in accordance with the leg...

Страница 11: ...5 Immunity to Voltage Interruptions AC Power Port Pass IEC 61000 4 11 2004 In Track charging system stand testing 2 7 Table 4 Immunity to Electrostatic discharge Enclosure Port Pass IEC 61000 4 2 2008...

Страница 12: ...or injuries to people within the area of the Hoist When using a sharp knife be careful not to damage the product This section will summarize the layout of the Hoist Packaging and what is included in...

Страница 13: ...is not intended to be used in environments where there are rapid changes in the environmental temperature and humidity during intended use This manual covers the safety and advice for the CP and movi...

Страница 14: ...e hoist in the following way 1 On the hook move the locking mechanism into the hook by pressing down on the tab Figure 6 and 7 2 With the carry bar positioned sideways along the length of the bar move...

Страница 15: ...t is fully understood should the sling loops be fitted onto the carry bar in the correct order Sling loops should be attached as follows 1 Put the required sling loop onto your finger and thumb and th...

Страница 16: ...oist are shown below in Table 5 complete with product codes Size Mackworth Sling Range Product Material and Code Polyester Solid Polyester Mesh Parasilk Quilted Supersoft Spacer Mackworth Oak Small 12...

Страница 17: ...201HZ5100 1201HZ4100 XXXL 1201HZ7000 1201HZ8000 1201HZ3000 1201HZ5000 1201HZ4000 Mackworth Hazel with head support Small 1201HZ7520 1201HZ8520 1201HZ3520 1201HZ5520 1201HZ4520 Medium 1201HZ7420 1201HZ...

Страница 18: ...01PN7420 1201PN8420 1201PN3420 1201PN5420 1201PN4420 Large 1201PN7320 1201PN8320 1201PN3320 1201PN5320 1201PN4320 XL 1201PN7220 1201PN8220 1201PN3220 1201PN5220 1201PN4220 XXL 1201PN7120 1201PN8120 12...

Страница 19: ...Medium Large CA500PML CA500MML CA500SML CA500PAML Large CA500PL CA500ML CA500SL CA500PAL X Large CA500PXL CA500MXL CA500SXL CA500PAXL CA501 Toilet Access with crossover straps P1 CA501PP1 CA501MP1 CA...

Страница 20: ...03EPXS n a n a n a Small CA503EPS n a n a n a Medium CA503EPM n a n a n a Large CA503EPL n a n a n a X Large CA503EPXL n a n a n a CA600 Hammock P1 CA600PP1 CA600MP1 CA600SP1 CA600PAP1 P2 CA600PP2 CA6...

Страница 21: ...CA701HSPAP3 P4 CA701HSPP4 CA701HSMP4 CA701HSSP4 CA701HSPAP4 P5 CA701HSPP5 CA701HSMP5 CA701HSSP5 CA701HSPAP5 X Small CA701HSPXS CA701HSMXS CA701HSSXS CA701HSPAXS Small CA701HSPS CA701HSMS CA701HSSS CA...

Страница 22: ...702HSSML CA702HSPAML Large CA702HSPL CA702HSML CA702HSSL CA702HSPAL X Large CA702HSPXL CA702HSMXL CA702HSSXL CA702HSPAXL CA703 Split Leg In Chair Hammock P1 CA703PP1 CA703MP1 CA703SP1 CA703PAP1 P2 CA7...

Страница 23: ...e perpendicular to the front face of the Hoist If the alignment is not perfect slowly rotate the handset until you feel the plug locating into the socket The Electrical handset is connected to a femal...

Страница 24: ...or the DOWN arrow button on the handset the carry bar can be raised or lowered to the correct height for attaching the sling or positioning an individual The UP DOWN functions of the handset buttons a...

Страница 25: ...ther end of the track system This dock is also the charging dock for the hoist as it is charged through the handset To store the handset after use traverse the hoist back to its charging location and...

Страница 26: ...nties and may cause damage to the hoist When Charging has completed ensure that the Blue rubber bung at the base of the handset is inserted back into the charging port This ensures that the stated IP...

Страница 27: ...ion The unit will continue beeping until the red button is released NOTE The emergency lowering function does not provide a lifting function The Emergency Lower should only be used in an emergency suc...

Страница 28: ...of where the hoist is in the track system There are no necessary modifications required for the device to perform its intended use However should the device or the installed system require modificatio...

Страница 29: ...ng Speed 130kg 25 38 mm s Lifting Speed 200kg 20 86 mm s Lowering Speed 0kg 27 02 mm s Lowering Speed 50kg 34 72 mm s Lowering Speed 100kg 35 21 mm s Lowering Speed 130kg 36 04 mm s Lowering Speed 200...

Страница 30: ...Electromagnetic disturbances Requirements and tests EN 60601 1 6 2010 Medical electrical equipment General requirements for basic safety and essential performance EN 60601 1 11 2015 Medical electrical...

Страница 31: ...professional The following specifies the importance of correct disposal procedure including local laws and being environmentally friendly Please observe the local laws on recycling and respect the cu...

Страница 32: ...section 5 5 Charging the Hoist Charge the hoist for at least one hour and then try to raise lower the carry bar If none of these resolve the fault DO NOT use the Hoist Contact your local authorised d...

Страница 33: ...s of the device through reference to the LED s shown on the hoist unit Find the fault and complete the recommended solution If the fault is not found and or the solution does not correct the problem c...

Страница 34: ...ange a service Need to ascertain necessary information for replacement parts and components Contact details of your local Prism Medical UK dealer are shown on the last page of this manual 11 2 Inspect...

Страница 35: ...rrectly with the QRS locking mechanism closed Ensure that the Trolley is able to swivel smoothly without restraint Lift Tape Caution The image Figure 44 indicates a badly worn lift tape due to an acum...

Страница 36: ...of the device should be for 5 minutes to prevent any virucidal infections without a degradation to the functionality of the device 5 minutes is a recommended contact time The device can withstand a l...

Страница 37: ...ata Sheet For a full review of the data please follow the link below http www nhsggc org uk media 236215 msds actichlor plus pdf 12 0 Warranty This guarantee does not affect or in any way limit your S...

Страница 38: ...999016 Revision G P a g e 38 of 44 13 0 Service Record History Complete this section after each service repair inspection and or maintenance...

Страница 39: ...999016 Revision G P a g e 39 of 44...

Страница 40: ...999016 Revision G P a g e 40 of 44...

Страница 41: ...999016 Revision G P a g e 41 of 44...

Страница 42: ...999016 Revision G P a g e 42 of 44 User notes...

Страница 43: ...999016 Revision G P a g e 43 of 44 User notes...

Страница 44: ...al UK for any errors or omissions Prism Medical UK operates a policy of continuous improvement Specifications and other data are subject to change without notice Dealer contact details Prism Medical U...

Отзывы: