2.3 Jumper Options
Various configurations of the Utility Module are possible by altering jumper positions, or
selecting alternative headers for the connection of the Utility Panel connectors. The figure
and table below describe these options:
Jumper/Header
Function
CN1
Coaxial Ref Sync output (WCK, SCK, DARS)
CN2
XLR Ref Sync output (DARS)
CN4
Digital Monitor #1, balanced output for XLR (note 1)
CN5
Analogue Monitor, left channel, unbalanced output (note 1, 2)
CN6
Analogue Monitor, left channel, balanced output
CN7
Digital Monitor #1, unbalanced output for coaxial
CN8
Digital Monitor #2, balanced output for XLR (note 1)
CN9
Digital Monitor #2, unbalanced output for coaxial (note 1)
CN10
Right-channel, analogue monitor unbalanced output (note 1, 2)
CN11
Right-channel, analogue monitor balanced output
CN12
XLR Ref Sync input (DARS)
CN13
Coaxial Ref Sync input (WCK, DARS or video)
CN14
RS-232 COM port (plug 9wD ribbon here for RS-232, default)
CN15
RS-422/485 COM port (plug 9wD ribbon here for RS-422/485)
CN16
Alternative MIDI connector for panel with DIN connectors
CN17
MIDI COM port (plug 9wD ribbon here for MIDI)
LK1
Coaxial Ref Sync out format; 3-5, 4-6: WCK (default); 1-3, 2-4: S/PDIF
LK2
Digital Monitor #1 output format; 1-2: AES3; 2-3: S/PDIF (default)
LK3
Digital Monitor #2 output format; 1-2: AES3; 2-3: S/PDIF (note 1)
LK4
XLR sync input termination: fitted : 110R (default); not fitted: none
LK5
Coaxial sync input termination: fitted : 75R (default); not fitted: none
LK6
RS-232 COM-mode: fitted – RS-232 mode (default), not fitted - other
LK7
Terminate RS-422/485 Rx: fitted – 110R term, not fitted - none
LK8
RS-485 mode: fitted – RS-485 (half -dplx), not fitted RS-422 (full-dplx)
LK9
RS-485 mode: fitted – RS-485 (half -dplx), not fitted RS-422 (full-dplx)
LK10
RS-422/485 COM-mode: fitted – RS-422/485 mode, not fitted - other
LK11
MIDI COM-mode: fitted - MIDI mode, not fitted - other
Note 1: Unused in default configuration
Note 2: It is recommended that the ‘balanced’ configuration be used for analogue Monitor outputs at all times, even if
the cold leg is grounded. The bootstrapping output circuit gives best results in this mode. The unbalanced connector
gives 6dB gain reduction and may produce increased distortion.