![Prism Sound ADA-8 Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/prism-sound/ada-8/ada-8_module-reference_1603549037.webp)
Prism Sound ADA-8XR Multi-channel A/D D/A Converter Module Reference - Revision 1.01
© Prism Media Products Limited, 2001-2005
Page 3.36
Having connected the ADA-8XR as above, switch it on and load the ‘
ProT HD 2xADC
’ Store.
This is located in Bank 1, Store 1.
7.7.4 Connecting a 16DA ADA-8XR as a 192 I/O
ADA-8XRs equipped with 16 analogue outputs are fitted with two Pro Tools HD I/O Modules.
The Module in the upper DIO Slot is designated ‘D1’, and the lower ‘D2’. Connect the
Primary Port of ‘D1’ to the desired Core or Process card in the workstation, and the
Expansion Port of ‘D1’ to the Primary Port of ‘D2’ using standard DigiLink cables. A further
Digidesign or Prism Sound I/O can be connected to the Expansion Port of ‘D2’ in the usual
way. The Wordclock I/O BNCs on the Utility Module are used for Loop Sync I/O if required.
Having connected the ADA-8XR as above, switch it on and load the ‘
ProT HD 2xDAC
’ Store.
This is located in Bank 1, Store 1.
7.7.5 Connecting an ADA-8XR to the ‘Legacy Port’ of a 96 I/O or a 192 I/O
An ADA-8XR fitted with a Pro Tools I/O Module (i.e. a pre-HD Pro Tools module) can be
connected to the ‘Legacy Port’ of a 96 I/O or a 192 I/O in the same way as a Digidesign
888|24. In this case, the ADA-8XR should be loaded with the ‘
ProT:SLAVE
’ Store. No sync
connections are required since the ADA-8XR obtains its sync from the Legacy Port. The
maximum sample rate supported is 48kHz.
7.7.6 Synchronization
If more than one I/O is used (unless only two ADA-8XRs are used, emulating a single 192
I/O), the usual ‘Loop Sync’ scheme should be used, wherein the Loop Sync output of one I/O
is connected to the Loop Sync input of the next, and so on until the output of the last I/O feeds
the input of the first. If a Digidesign SYNC I/O is used, this should be included in the Loop
Sync in the usual way.
If external sync is to be connected via an ADA-8XR (e.g. from a digital input, or from an
AES11 ref sync input), this can be selected from the Pro Tools|HD user-interface in the
normal way. If the external sync is a wordclock, the Loop Sync must be broken at the
designated ADA-8XR, since its wordclock input is needed to connect the external sync. Note
that sync cannot be provided from a digital input of the ‘Sub’ ADA-8XR in a pair, since the
‘Sub’ is always a sync slave to the ‘Main’ ADA-8XR.