Inspection  

Inspection is to be completed prior to each use by the user of the Gantry. 

 

Should any of the components in the table below fail the inspection, DO NOT use gantry. 

Contact your local authorized dealer for service – contact details are on the last page of this manual. 

 

Ensure all component inspections in the Table below are completed prior to each use of the Hoist.  

 

Check List before Use 

Component 

Service/Inspection required 

Generic 

Visual inspection of the external of the Gantry. Significant damage that may affect 

the function of the Gantry along with a clear safety hazard is unacceptable. 

Check the Labelling on the Gantry to ensure they are all still legible, this includes 

the Serial Number and other important markings. If labels are not legible, then 

contact your local authorised dealer immediately.

 

Check all main nuts and bolts to see if they are loose, If they are not tight or you 

have concerns, then contact your local authorised dealer immediately.

 

Certification

 

An authorised/competent service company or person will issue a test certificate 

after satisfactory completion of the LOLER inspection. The certificate will be valid 

for 6 months.

 

Telescopic track  

Check the smooth opening and closing of the track. 

Telescopic legs  

Ensure the telescopic legs are fully engages into each foot  

Track

 

Check the attachment of the track to the Legs, ensure all fixing points are secure 

and free from wear.

 

Trolley

 

Check the trolley rotates and traverses freely. Check the central pivot bolt and 

nylon lock nut for excessive wear. Check the fixing point for excessive wear and 

inspect the hooks for any damage, sharp edges and excessive wear.

 

 

8.3

 

Cleaning

 

Please follow the cleaning guidelines below on cleaning and disinfecting the Gantry. 

 

 

General cleaning 

It is recommended to clean the FSG440 and accessories before the use by a different patient, reducing the risk of 

cross–contamination. 

 

The exterior of the FSG440 can be cleaned using a damp soapy cloth for general cleaning duties. Please ensure the cloth is damp 

and not wet. Ensure the exterior of the device is dry after cleaning. Dry using a clean dry cloth. 

 

 

 

 

 

 

 

 

 

 

Table 8

 

Содержание mackworth FSG440

Страница 1: ...Doc No 999548 Revision of document B Revision Date 09 12 2021 FSG440 Portable Gantry User Manual...

Страница 2: ...s Key Parts 7 Final Inspection 8 Technical Specification 9 4 1 FSG Gantry Dimensions 9 4 2 Specifications 9 4 3 Expected Product Lifetime 10 4 4 Standards Applied 10 Environmental Storage and Operatin...

Страница 3: ...with the documents included with the FSG440 Contents of this manual are subject to change without prior written notice Do not attempt to use this equipment without first understanding the contents of...

Страница 4: ...l represents Consult instructions before use Caution see instructions for use Manufacturer Safe Working Load represents the maximum load rated for safe operation Packaging indicator This way up Date o...

Страница 5: ...flat and levelled surface prior to use The FSG440 must be installed only by persons authorized by Mackworth or who have the rights to install and commission the Gantry safe for use Under no circumstan...

Страница 6: ...tested to exceed BS EN 10535 2006 This does not mean that it can be used without care ALL OPERATORS should have read the operating instructions and appreciate this warning section 1 FSG440 are less s...

Страница 7: ...ystem The image below shows the contents of the free standing gantry If you have not received all the components contact your Mackworth dealer immediately contact details are provided on the last page...

Страница 8: ...ist accessory and sling user guides for specific details regarding their inspection Prior to mounting the portable lift onto the trolley of the FSG440 please read the owner s manual of the portable li...

Страница 9: ...8 7 Lowest Height 2141 mm 84 3 Maximum length 3387mm 133 3 Minimum Length 2445mm 96 3 Internal maximum clearance 3052mm 120 2 Internal minimum clearance 2102mm 82 8 Operational Forces Latch 3N Moving...

Страница 10: ...up to 90 35 C to 70 C 95 F to 158 F non condensing at a water vapour pressure up to 50hPa Disposal When the FSG440 has completed its life cycle and can no longer perform to its intended use safely the...

Страница 11: ...arried out on a Mackworth FSG440 while transferring a person to reduce the risk of injury Service must be completed by a Mackworth authorised Service Engineer Do not attempt to service the product you...

Страница 12: ...ised dealer immediately Certification An authorised competent service company or person will issue a test certificate after satisfactory completion of the LOLER inspection The certificate will be vali...

Страница 13: ...s of the device should be for 5 minutes to prevent any virucidal infections without a degradation to the functionality of the device 5 minutes is a recommended contact time The device can withstand a...

Страница 14: ...MSDS Manufacturers Safety Data Sheet For a full review of the data please follow the link below http www nhsggc org uk media 236215 msds actichlor plus pdf Warranty This guarantee does not affect or...

Страница 15: ...999548 Revision B P a g e 15 of 20 10 0 Service Record History Complete this section after each service repair inspection and or maintenance...

Страница 16: ...999548 Revision B P a g e 16 of 20...

Страница 17: ...999548 Revision B P a g e 17 of 20...

Страница 18: ...999548 Revision B P a g e 18 of 20...

Страница 19: ...999548 Revision B P a g e 19 of 20 User notes...

Страница 20: ...y errors or omissions Mackworth operates a policy of continuous improvement Specifications and other data are subject to change without notice Dealer service contact details Manufactures Contact detai...

Отзывы: