background image

 

 

 

Section

 

4

   

 

 

 

 

 

 

 

Operation

 

4.1

 

Ignition

 

Refer

 

to

 

the

 

section

 

below

 

according

 

to

 

which

 

ignition

 

system

 

you

 

purchased.

 

An

 

initial

 

burner

 

test

 

should

 

be

 

done

 

prior

 

to

 

filling

 

the

 

pan

 

with

 

media

 

(rocks/glass/etc.)

 

4.1.1

 

Manual

 

Light

 

You

 

will

 

need

 

a

 

fireplace

 

lighter,

 

do

 

not

 

use

 

a

 

match

 

or

 

cigarette

 

lighter

 

as

 

they

 

are

 

much

 

shorter

 

and

 

will

 

light

 

the

 

fuel

 

too

 

close

 

to

 

the

 

burner

 

which

 

may

 

result

 

in

 

serious

 

injury.

 

Ignite

 

your

 

fireplace

 

lighter

 

and

 

hold

 

the

 

tip

 

close

 

to

 

the

 

burner.

 

Insert

 

fire

 

table

 

key

 

and

 

turn

 

it

 

to

 

the

 

ON

 

position

 

to

 

start

 

gas

 

flow

 

to

 

the

 

burner

‐ 

if

 

you

 

are

 

using

 

a

 

propane

 

tank

 

unit,

 

please

 

note

 

you

 

will

 

need

 

to

 

open

 

the

 

valve

 

on

 

your

 

tank

 

first.

 

If

 

your

 

burner

 

does

 

not

 

light

 

within

 

5

 

seconds,

 

turn

 

key

 

to

 

the

 

OFF

 

position

 

and

 

wait

 

10

 

seconds

 

before

 

trying

 

again.

 

If

 

the

 

burner

 

still

 

does

 

not

 

light,

 

call

 

your

 

local

 

gas

 

technician

 

to

 

determine

 

if

 

there

 

is

 

a

 

problem.

 

Once

 

burner

 

lights,

 

immediately

 

remove

 

your

 

hand

 

and

 

allow

 

burner

 

to

 

operate

 

for

 

a

 

few

 

minutes

 

before

 

turning

 

it

 

off.

 

Make

 

sure

 

the

 

valve

 

is

 

properly

 

closed

 

every

 

time

 

you

 

leave

 

your

 

fire

 

feature

 

unattended

 

and

 

remove

 

key.

 

For

 

propane

 

units,

 

ensure

 

that

 

valve

 

on

 

tank

 

is

 

completely

 

closed

 

when

 

fire

 

feature

 

is

 

not

 

use.

  

You

 

are

 

now

 

ready

 

to

 

place

 

the

 

fire

 

media

 

onto

 

the

 

burner

 

pan.

 

Slowly

 

pour

 

media

 

onto

 

pan

 

and

 

spread

 

evenly.

 

Fire

 

media

 

should

 

be

 

sparsely

 

spread

 

out

 

enough

 

to

 

cover

 

pan.

 

Only

 

use

 

the

 

recommended

 

amount

 

of

 

media

 

in

 

your

 

unit

 

(the

 

amount

 

provided),

 

overfilling

 

may

 

result

 

in

 

smaller

 

flame

 

and

 

gas

 

buildup

 

which

 

may

 

cause

 

an

 

explosion.

 

Fresh

 

air

 

must

 

be

 

able

 

to

 

pass

 

through

 

the

 

unit.

 

Do

 

not

 

block

 

or

 

obstruct

 

any

 

vents

 

on

 

lower

 

and

 

upper

 

parts

 

of

 

the

 

fire

 

feature.

 

These

 

are

 

designed

 

to

 

ensure

 

proper

 

combustion

 

and

 

ensure

 

no

 

buildup

 

of

 

residual

 

gases

 

within

 

the

 

unit.

 

4.1.2

 

Battery

 

Ignition

 

*only

 

available

 

for

 

Propane

 

Gas

 

Units

 

Find

 

the

 

panel

 

on

 

the

 

side

 

of

 

your

 

unit,

 

the

 

knob

 

should

 

be

 

at

 

the

 

12:00

 

position.

 

This

 

type

 

of

 

ignition

 

takes

 

one

 

AA

 

battery

 

(not

 

included).

 

To

 

insert

 

battery,

 

turn

 

the

 

black

 

battery

 

receptacle

 

to

 

the

 

left

 

of

 

the

 

knob

 

counter

clockwise

 

until

 

it

 

unscrews

 

and

 

comes

 

off.

 

Insert

 

battery

 

and

 

carefully

 

place

 

receptacle

 

knob

 

back

 

in

 

position

 

and

 

screw

 

back

 

on.

 

You

 

may

 

need

 

to

 

apply

 

light

 

pressure

 

but

 

do

 

not

 

overtighten

 

as

 

it

 

may

 

damage

 

the

 

knob

 

and

 

threads.

 

To

 

ignite

 

unit,

 

ensure

 

knob

 

is

 

in

 

the

 

12:00

 

position

 

to

 

start.

 

Push

 

the

 

knob

 

inward

 

and

 

turn

 

clockwise

 

to

 

the

 

6:00

 

position.

 

You

 

should

 

hear

 

the

 

igniter

 

sparking

 

and

 

the

 

gas

 

should

 

ignite.

 

Continue

 

to

 

push

 

knob

 

inward

 

until

 

burner

 

lights,

 

wait

 

a

 

few

 

seconds

 

and

 

release

 

knob.

 

If

 

the

 

flame

 

does

 

not

 

stay

 

lit,

 

push

 

the

 

knob

 

back

 

in

 

and

 

allow

 

spark

 

to

 

reignite.

 

If

 

you

 

do

 

not

 

hear

 

the

 

igniter

 

sparking,

 

your

 

battery

 

may

 

be

 

drained

 

and

 

will

 

require

 

replacement.

 

Regulate

 

the

 

flame

 

by

 

turning

 

the

 

knob

 

clockwise

 

until

 

it

 

is

 

to

 

your

 

liking.

 

The

 

knob

 

will

 

not

 

go

 

past

 

the

 

9:00

 

position.

 

If

 

the

 

flames

 

are

 

still

 

too

 

low

 

or

 

too

 

high,

 

have

 

the

 

pressure

 

regulator

 

checked

 

for

 

proper

 

Содержание Cilindro

Страница 1: ......

Страница 2: ...eneral Description 1 1 Receiving Checklist 1 2 Product Dimensions 1 3 Product Contents 1 4 Safely Moving Unit Section 2 Safety Instructions Section 3 Installation Details 3 1 Gas Requirements 3 2 Inte...

Страница 3: ...perwork on crate pallet 3 Open top of crate pallet and inspect unit for damage If damaged please notify carrier immediately and sign damaged or do not receive Please also notify Prism Hardscapes offic...

Страница 4: ......

Страница 5: ...r Pan 1 1 2 Female to Male Orifice 1 1 2 Female to Flare Male Inlet Pipe 1 1 2 Flex Line Hose 1 Propane Gas Hose For Propane Gas Units Only 1 1 2 Flare 2 1 2 Ball Valve 1 Chrome Plated Cover 1 1 1 4 x...

Страница 6: ...ASED STABILITY WHILE MOVING USE DOLLY TO NAVIGATE THE UNIT TO THE FINAL POSITION CAREFULLY REMOVE UNIT FROM CRATE AND PLACE ONTO MOVING DOLLY PLACE FIRE FEATURE WITH BASE DOWN TO MOVE PLACE FIRE FEATU...

Страница 7: ...and instructions provided with this product Failure to do so may result in property damage personal injury and or death Improper installation and or operation may result in exposure to carbon monoxid...

Страница 8: ...se fire feature in windy conditions Do not touch hot surfaces hot media rocks glass etc or open flames Do not reach jump or walk across unit media or open flames Do not ignite fire feature when media...

Страница 9: ...to fire feature Once you have created a trench underground for your pipe the stubbed out end should be fitted with a NPT ball valve shutoff rated for gas usage and a flare fitting sized for the same...

Страница 10: ...h do not hand tighten An additional flex hose will be attached to the other end of the key valve to the flare fitting at the bottom of the burner The arrow on the key valve should be pointing the dire...

Страница 11: ...ly use the recommended amount of media in your unit the amount provided overfilling may result in smaller flame and gas buildup which may cause an explosion Fresh air must be able to pass through the...

Страница 12: ...obstruct any vents on lower and upper parts of the fire feature These are designed to ensure proper combustion and ensure no buildup of residual gases within the unit 4 1 3 Electronic Ignition Prism...

Страница 13: ...to Fix Improper Gas Pressure Propane Gas Units Check if tank is low or empty may need to be refilled or replaced Natural Gas Units Have a gas professional confirm gas pressure Improperly Applied Fire...

Страница 14: ...ry by emailing tech support prismhardscapes com UNIT PRODUCING UNWANTED ODORS Possible Cause How to Fix Gas Leak DO NOT OPERATE Turn off key valve but leave gas source on open The gas should be flowin...

Страница 15: ...unit Prism Hardscapes will not be responsible for any defects resulting from misuse user error installation error abuse repair or alteration The use of wood or fuels other than those specified for use...

Страница 16: ......

Отзывы: