254764-001 Rev B 23
High Density Focus: Analyze bar codes with 5 mil X dimension
Custom focus distances are available to achieve various spot sizes – contact PRINTRONIX Technical
support for details.
Power
•
+5 Volts DC, +/- .25 Volt
•
1 amp maximum
Sync
See the Sync Inputs Section for more details
I/O connector pin 4 input:
•
ttl switching level threshold
•
Maximum input voltage swing: +/- 12 VDC
•
100 K ohm internal pull-up resistor to 5 volts DC
I/O connector pins 1 (+), 2 (-) isolated input:
•
24 Volts DC nominal input for sensing
•
30 Volts DC maximum input, approximately 15 Volts minimum for sensing
•
This input is ground isolated from 5 VDC power
•
Sync input recovery time: 12.5 milliseconds minimum
Outputs
•
Open Drain FET (Field Effect Transistor) – no internal pull-up resistor
•
External Pull-up Voltage: 0 - 30 Volts DC
•
Sink current: 100 milliamps maximum
SYMBOLOGIES
•
USS Code 128
•
USS Code 39
•
USS Code 93
•
USS Codabar
•
USS Interleaved 2 of 5
•
UPC versions A and E (including 2 and 5 digit supplemental codes)
•
EAN-13 and EAN-8 (including 2 and 5 digit supplemental codes)
OPERATION MODES
The SV 2 Series is very flexible, with many programmable features, but basic system operation can be
broken down into three modes. Two modes include a sync signal and one mode operates without a sync
signal. These modes are programmable via SV Command Language and PRINTRONIX ScanVision
software.
Sync Mode – Moving Bar Codes
In this mode, a sync signal is used as an indicator to determine when an object or label containing a bar
code(s) has entered or exited the laser beam. Bar codes are analyzed and ports activated, transmissions sent,
etc. as the bar codes pass through the beam. The SV unit is programmed for the number of bar codes to
expect during a sync period (see Sync Input Section), therefore the SV unit can detect missing or
undetectable bar codes.
A hardware input is the most common sync source for this mode.