Product Holding Bin
DHB2PT-33
DQ
Series
CastleNet® Communications Network
The Prince Castle DHB-BK Bins and Retro Bun Timer and New Bun
Cabinet Timers can be inter-connected to form the CastleNet
®
Communication Network. The network can be used for data transfer
between bins and timers for menu updates or to transfer product hold
time from bin-to-bin. A PDA (or similar device) or a notebook with Prince
Castle MenuView
®
software is used to connect to the network and enter
the desired changes.
Each bin is supplied with a standard 25' cable and allows units to be
“daisy-chained” together to form the network. If cable is too short, use
Prince Castle Extender Cable Kit, P/N PC-COMEXT.
The factory default address for Main bins and timers is address
1
.
The factory default address for Specialty bins and timers is address
2
.
If a third bin is used, the address must be set at
3
.
The factory default address for the Retro Bun Timer is
bunF
.
IN
OUT
EXTERNAL
IN
OUT
EXTERNAL
IN
OUT
EXTERNAL
RETRO
BUN
TIMER
BIN 1
BIN 2
BIN 3
Telephone jack plugs are located on the back of the unit.
Connect the units using the cables provided as shown here.
Bin 1
Bin 2
Bin 3
IMPORTANT: Each timer must have a different address.
If a location has three bins, it is recommended that the bins
and timers be set consecutively to addresses 1 through 3.
A. Turn the power switch off, wait 15 seconds. Turn the switch
to ON while pressing and holding the ACTUAL and SET-
POINT buttons. The display will show the current bin
address.
B. Continue to hold the buttons until PROG LED turns on.
p r o g
UPPER
PROG
LOWER
ACTUAL
TEMP
SET-
POINT
b a r 3
UPPER
PROG
LOWER
ACTUAL
TEMP
SET-
POINT
Available addresses are:
bin1
thru
bin9, binA, binB, binC, binD, binE
and
binF.
IMPORTANT: Continue to step 5 to
check the timer address. No two
timers can have the same address.
Use the UP or DOWN Arrow buttons to scroll to the desired
address. Press the PRINCE CASTLE LOGO Button to store the
new address.
EGGS
EGGS
EGGS
MENU
ENTER
B
RE
TRANSFER
bar2
To check the timer address, press and hold the PRINCE
CASTLE LOGO button and the DOWN Arrow button.
The current timer address will be displayed in the far right timer
display.
To change the timer address, proceed to step 6.
⇑
⇑
ADDR
SET
MENU
ENTER
TRANSFER
bar2
To change the timer address, turn the unit power switch off and
wait 15 seconds. Turn the power switch back on and immedi-
ately press and hold the PRINCE CASTLE LOGO button and the
DOWN Arrow button for approximately 6 seconds or until the
display shows
SET ADDR
⇑ ⇓
BAR2.
The address number will blink on/off.
⇑
⇑
ADDR
MENU
ENTER
BKFT
REG
bar3
Use the UP or DOWN Arrow button to scroll to the desired
address. Press the MENU/ENTER button to store the new
address and return to normal operating mode.
Available addresses are:
bin1
thru
bin 9, binA, binB, binC, binD, binE
and
binF.
b a r 2
UPPER
PROG
LOWER
ACTUAL
TEMP
SET-
POINT
Example
Example
6
4
5
7
2
1
3
Printed in USA
10/10
© 20
10
10 541-553rev
C_EN