background image

541-553rev

C_EN

     Printed in USA

10/10 

© 20

10

BISC

SAUS

BACN

MENU

ENTER

BKFT

REG

TRANSFER

EGGS

BACN

SAUS

SAUS

BACN

REG

BKFT

MENU

ENTER

TRANSFER

Product Holding Bin

Product Holding Bin

DHB2PT

DHB2PT

-33

DQ

 Series

-33

DQ

 Series

Operation

Operation

Manual

Manual

355 East Kehoe Blvd. • Carol Stream, IL 60188

Phone: 630-462-8800 • Toll Free: 1-800-PCASTLE

Fax: 630-462-1460 • www.princecastle.com

LIMITED WARRANTY

This product is warranted to be free from defects in material and/or workmanship 

for a period of 1 year from date of original installation, not to exceed 18 months 

from the date of manufacture.
Any component which proves to be faulty in material and/or workmanship will be 

replaced or repaired (at the option of Prince Castle, Inc.) without cost to the customer 

for parts and labor. This warranty covers on-location service (i.e. trip charges and/or 

mileage). Travel mileage is limited to 100 miles (200 Kilometers) round trip (one trip 

warranty) from an authorized service agency or its sub-service agency.
This warranty is subject to the following exceptions/conditions:
•  Use of any non-genuine Prince Castle parts voids this warranty.
•  All labor to be performed during regular work hours. Overtime premium (the 

incremental amount) will be charged to the customer.

•  Damage caused by carelessness, neglect and/or abuse (e.g., dropping, 

tampering or altering parts, equipment damaged in shipment, by fire, flood or 

an act of God) is not covered under this warranty.

•  All problems due to operation at voltages other than that specified on 

equipment nameplates are not covered by this warranty. Conversion to correct 

voltage is the customer’s responsibility.

•  This equipment must be serviced by Prince Castle Authorized Service Agency or 

a Prince Castle Service Technician during the warranty period.

TABLE OF CONTENTS

Product Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Safety Information  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Cleaning  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4–9
CastleNet Communications Network  . . . . . . . . . . . . . . .10
Factory Presets  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Wiring Diagram  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Parts List & Exploded View . . . . . . . . . . . . . . . . . . . . . . .13

LED Timers (tri-color)

Pan Buttons 

Power On/Off Switch

Temperature Control

Panel

PRINCE CASTLE 

LOGO Button

Pan & Pan Cover

Button Bar

Transfer Button

Lower Pan Displays

Upper Pan Displays

MENU/ENTER

Button

BKFT (Breakfast)

LED

UP and DOWN 
Arrow Buttons

REG (Regular Menu)

LED

Product Identification

Содержание DHB2PT-33DQ Series

Страница 1: ...nditions Use of any non genuine Prince Castle parts voids this warranty All labor to be performed during regular work hours Overtime premium the incremental amount will be charged to the customer Damage caused by carelessness neglect and or abuse e g dropping tampering or altering parts equipment damaged in shipment by fire flood or an act of God is not covered under this warranty All problems due...

Страница 2: ...ents additions or replacements for previously purchased equipment WARNING Indicates information important to the proper opera tion of the unit Failure to observe may result in dam age to the equipment and or severe bodily injury or death CAUTION Indicates information important to the operation of the unit Failure to observe may result in damage to the equipment Model Volts Hz Watts Amps Plug Numbe...

Страница 3: ...pan is active for a product the LED for the first pan loaded will turn from RED to GREEN The LED for the 2nd pan 3rd pan etc loaded will turn from RED to YELLOW An LED timer can be stopped cancelled at any time by pressing and releasing the corresponding PAN Button LED Timers RED RED RED RED GREEN GREEN GREEN GREEN YELLOW YELLOW REG BKFT MENU ENTER TRANSFER Discard product Cook more product Cook m...

Страница 4: ... CAUTION This unit is not watertight Do not clean with a water jet jet spray Do not immerse the unit in water The unit has four shelves each with an upper and lower heater eight heaters total The factory pre set for the upper heaters is 195 F The factory pre set for the lower heaters is 185 F Each upper heater has a programmable range of 150 275 F Each lower heater has a programmable range of 150 ...

Страница 5: ...w Buttons until the desired setpoint temperature is displayed U2 30 UPPER PROG LOWER ACTUAL TEMP SET POINT U225 UPPER PROG LOWER ACTUAL TEMP SET POINT Press and hold the PRINCE CASTLE LOGO and ACTUAL Buttons for 5 seconds The semi colon LED indicator will light The temp dis played is the actual heater tempera ture sensed by the controller U2 20 UPPER PROG LOWER ACTUAL TEMP SET POINT Press the UP o...

Страница 6: ...e display to be changed The LED will change from red to yellow and the display will change from PROG to the assigned menu item When scrolling menu numbers appears in this display MNU1 MENU ENTER BKFT REG R When the desired menu is displayed release the MENU ENTER button The food products for the menu will be displayed in the upper and lower PAN displays When timers for a different menu are still a...

Страница 7: ...ime When the desired hold time is displayed press the MENU ENTER button to save the desired hold time NOTE Hold time cannot be reduced to less than the Cook More time plus one minute NOTE Cook More time cannot be increased to more than the Hold time minus one minute 2 10 EGGS MENU ENTER TRANSFER ENTR HOLD B When the desired cook more time is displayed press the MENU ENTER Button to save it 10 EGGS...

Страница 8: ...t is displayed press the MENU ENTER button to select it The first letter in this case the E E will start blinking A The display will show EDIT PROD NAME Repeat Steps 2 4 for any other product B Press and release the PRINCE CASTLE LOGO button at any time to exit the Programming Mode and return to the Run Mode NOTE If the MENU ENTER button has not been pressed to save any changes the program will re...

Страница 9: ... to exit the Programming Mode and return to the Run Mode NOTE If the MENU ENTER Button has not been pressed to save any changes the program will revert to the original time TIME XFR MENU ENTER BKFT REG TRANSFER ENTR MAX A The SET MAXIMUM TRANSFER TIME menu is used to set the amount of time allowed to make a product transfer from one pan to another B Press and hold the PRINCE CASTLE LOGO Button the...

Страница 10: ...nds Turn the switch to ON while pressing and holding the ACTUAL and SET POINT buttons The display will show the current bin address B Continue to hold the buttons until PROG LED turns on prog UPPER PROG LOWER ACTUAL TEMP SET POINT bar3 UPPER PROG LOWER ACTUAL TEMP SET POINT Available addresses are bin1 thru bin9 binA binB binC binD binE and binF IMPORTANT Continue to step 5 to check the timer addr...

Страница 11: ...og Sauce CHLI 30 3 Bacon BACN 30 3 Special 1 SPC12 30 3 Special 2 SPC22 30 3 Special 3 SPC32 30 3 Special 4 SPC42 30 3 Special 5 SPC52 30 3 Special 6 SPC62 30 3 Special 7 SPC72 30 3 Special 8 SPC82 30 3 Special 9 SPC92 30 3 Special A SPCA2 30 3 Special B SPCB2 30 3 Special C SPCC2 30 3 Special D SPCD2 30 3 Special E SPCE2 30 3 Special F SPCF2 30 3 1 Hold and Cook More times may be re programmed Se...

Страница 12: ...e is below 75 F Heater inoperable Probe inoperable Relay inoperable Temperature is above 300 F abnormal operation Probe is inoperable Replace power circuit board Replace power circuit board Test heater resistance 150 2 Ohms Replace heater if necessary Verify ribbon cable connection Normal display during warmup Test heater resistance 150 2 Ohms Check for open thermocouple wires from probe Replace h...

Страница 13: ...er Cord Kit 14 76 724 Screw Socket 8 32 x 3 4 15 541 359S Lower Heater Assy 230 Volt 16 541 376S Upper Heater Assy 230 Volt 17 541 489 Chassis Right 18 541 129 Side Cover Bracket 19 541 369 Insulation 20 541 329 Top Cover 21 541 324 Header 22 541 650 Trim 23 541 383 Shelf Bracket 24 541 488 Chassis Left 25 541 317 Insulation 26 541 606 Base 27 197 232 Foot 28 541 323 Bottom Cover 541 479 Black Pan...

Страница 14: ...Product Holding Bin DHB2PT 33DQ Series NOTES Printed in USA 10 10 2010 14 541 553revBC_EN ...

Отзывы: