PROGRAMMING MANUAL
508913C PUBLICATION DATE 25 AUG 2006.DOC
DIAGNOSTIC MENU („DG“)
Displaying the state of inputs and outputs of the control unit with possibility to change the state of individual
outputs. Input to diagnostic mode is executed by set-up the item „dG“ in initialization to „On“ (by means
of „+“ and „-“ ) and confirmation by pressing „START“ button. Go to individual items in diagnostic mode by
means of buttons „+“ and „-“. Change of individual output state is possible to do by holding the button „START“.
Input
identification
Description
I1
Frequency inverter
I2
Manual crank
I3
Foot pedal of clutch
I4
Bimetal of ventilator
I5
Switch of programming
I6
Gas low pressure
I7
Alarm of gas ignition
I8
Finger protector guard
I9
Detection of linen (OPL) / coinmeter 1 (coin)
10
Incremental roller sensor - testing is not possible
11
Position of pressure roller 1 (OPL - ironer with
front/rear delivery) / coin meter 2
12
Position of pressure roller 2 (OPL - ironer with
front/rear delivery)
13
Trough position
14
Was not used
A1
Actual temperature of ironing roller
A2
Actual speed of ironing roller
Output
identification
Description
O1
Heating 1
O2
Heating 2
O3
Frequency inverter
O4
Blocking of clutch pedal
O5
Pressure roller
O6
Ventilator
O7
Reversation of roller direction
O8
Permit of inverter action
O9
Increased speed of inverter (for the first fold on linen)
10
Direction of cloths delivery
11,12,13
Was not used
A0
Speed of roller