background image

1.CONNECTION

Your stove is designed to connect directly on to 

a 3/8” LH BSP camping gas cylinder using the 

specially designed LP Gas hose supplied with 

the appliance.
1.  Check that the  

gas controls  

are in the “Off” 

position (turned 

fully clockwise).

2.  Take the stove 

connector head 

of the hose and 

attach to the 

gas inlet on the 

appliance, tighten 

up using fingers.

3.  Attach the other 

end of the hose to 

the gas cylinder, 

tightening using a 

spanner.

4.  Turn the cylinder 

gas valve on in 

an anti-clockwise 

direction for one 

full turn and 

then check the 

connections for 

leaks with soapy 

water, if a leak is 

detected turn the 

cylinder gas valve 

“Off” and retighten 

all connections 

then retest.

OPERATING THE APPLIANCE

1. Gas control
2. Burners
3.  Cylinder connection
4.  Stove connection
5. Hose
6. Wings

2

2

5

6

6

3

1

1

4

Содержание 509012

Страница 1: ...for use carefully Familiarise yourself with the appliance before connecting it to it s gas container Keep these instructions for future reference Distributed by PRIMUS AUSTRALIA PTY LTD Bundoora Victoria 3083 www primusaustralia com au Part No 509012 2 BURNER LP GAS STOVE OPERATING INSTRUCTIONS ...

Страница 2: ... of the appliance will become hot during operation please take care when handling or moving the appliance Appliance is to be used on a stable level flat non flammable surface the appliance should be protected from direct drafts and in a well ventilated place Only cooking vessels with a maximum diameter of 220mm are to be used with this appliance Take care that the primary air intakes located on th...

Страница 3: ...to the gas inlet on the appliance tighten up using fingers 3 Attach the other end of the hose to the gas cylinder tightening using a spanner 4 Turn the cylinder gas valve on in an anti clockwise direction for one full turn and then check the connections for leaks with soapy water if a leak is detected turn the cylinder gas valve Off and retighten all connections then retest OPERATING THE APPLIANCE...

Страница 4: ...o be used and to reduce the risk of blocked gas jets caused by excess gas being left in the hose all remaining gas must be expelled from the hose assembly 1 With the flame still operating turn the valve on the gas cylinder in the clockwise direction until it is Off Allow the flame to burn down then extinguish once all remaining gas in the hose has been used 2 Turn the gas controls on the appliance...

Страница 5: ... with walls on all sides but with no overhead cover B Within a partial enclosure that includes an overhead cover and no more than two walls C Within a partial enclosure that includes an overhead cover and more than two walls the following must apply 1 At least 25 of the total wall area is completely open 2 30 or more in total of the remaining wall side back and front wall areas is open and unrestr...

Страница 6: ...2 3 3 8 9 4 4 5 5 6 6 7 7 Spare Part List 1 PCS7012 Trivet 2 PCS6012 Large burner 3 PCS5012 Gas jet large burner 4 PCS8951 O ring for spindle 5 PCS8950 Spindle 6 PCS8952 Lock nut 7 PCS8949 Control knob 8 PCS8414 O ring for gas connector 9 HP1200F 1200mm gas hose WARRANTY This appliance is covered against faulty workmanship and materials for a period of 3 years from the date of original purchase Th...

Отзывы: