Applicable machine models 

Washer 

Dryer 

Ironer 

 

PW5

 

P6, P7

 

C6, 8

 

RS6, 7, 10

 

RS13, (16), 18, 22, 27, 35

 

FS6, 7, 10

 

FS16, 22

 

FS33, 40, 55

 

FS120

 

MB16, 26, 33

 

MB44, 66

 

MB90, 140, 180

 

 

 

DAM5 / DAMC5

 

DA9 / DAM(S)(T)9 

 

T9

 

T11, 13, 16

 

T1313

 

T24, 35

 

DA11, 13, 15

 

DA1313

 

D25, 35

 

D55, 77

 

 

Pony

 

I18, 25, 30

 

I35, 50

 

IF50 / IR50

 

IFF

 

Crossfolder

 

Stacker

 

 
 
 
 
 

 

Applicable type of spare parts 

Washer

 

Dryer 

Ironer 

 

General

 

Chasis

 

Shock absorbers

 

Cabinet

 

Controler

 

Coin unit

 

Electric components & sensors 

 

Heating unit

 

Inlet

 

Soap hopper

 

Motor & pulley & belts

 

Bearing house & seals

 

Drum

 

Door

 

Drain

 

 

 

General

 

Chasis

 

Cabinet

 

Controler

 

Coin unit

 

Electric components & sensors

 

Heating unit

 

Motor & pulley & belts

 

Bearing house & seals

 

Drum

 

Door

 

Air filter

 

Air fan

 

Exhaust

 

 

General

 

Chasis

 

Cabinet

 

Controler

 

Coin unit

 

Electric components & sensors

 

Heating unit

 

Inlet

 

Motor & pulley & chains

 

Bearing house

 

Ironer belts

 

Air filter

 

Air fan

 

Exhaust

 

Delivery system

 

Folding system

 

www.groupdynamics-laundry.com 

[email protected]

Содержание 40

Страница 1: ...NG Carry out the handling according to the following manufacturers instructions Always respect warnings from the relevant manuals of the machine Make sure all electric power or other energy sources are disconnected and closed before any servicing Always switch off the main switch Wait 10 minutes after electrical power is disconnected to eliminate power on the inverter terminals Installation mainte...

Страница 2: ...er Ironer General Chasis Shock absorbers Cabinet Controler Coin unit Electric components sensors Heating unit Inlet Soap hopper Motor pulley belts Bearing house seals Drum Door Drain General Chasis Cabinet Controler Coin unit Electric components sensors Heating unit Motor pulley belts Bearing house seals Drum Door Air filter Air fan Exhaust General Chasis Cabinet Controler Coin unit Electric compo...

Страница 3: ...Needed tools 2 Wrenches M13 For 1 ph inverter Wires 2 5mm length 50cm 4Pc preferably blue and black For 3 ph inverter FS16 23 FS33 400V RS27 35 Wires 2 5mm length 50cm 6Pc preferably black For 3 ph inverter FS33 200V FS40 FS55 Wires 4mm length 50cm 6Pc preferably black Drill Ø10mm for metal Wire cutting and wire stripping pliers 3 Part numbers Nr part number description Quantity 525927 H616 SERVIC...

Страница 4: ...h inverter 3x380 480V without N only Since there is used a transformer for the control circuit it is not possible to mount the AC reactor in the contactor box Therefor mount the AC reactor on the rear bridge beside the water valves Drill 4 holes diam 10mm and fix the AC reactor with the included bolts and nuts Make sure that no burs from the drilling can enter the frequency inverter or other compo...

Страница 5: ...525928 Instruction AC reactor FS16 55 RS27 35 P5 15 Make the electrical connection according the scheme and instructions below www groupdynamics laundry com sales groupdynamics lv ...

Страница 6: ...to terminals U1 and V1 of the AC reactor 3 ph inverter Connect these wires to terminals U1 V1 and W1 of the AC reactor 1 ph inverter Connect terminals U2 and V2 to the inverter contactor by new wires to the same terminals where you have disconnected the 2 other wires Terminals W1 and W2 of the AC reactor will not be used if the inverter is 1 phase 3 ph inverter Connect terminals U2 V2 W2 to the in...

Страница 7: ...the AC reactor on top of the box of the frequency inverter Drill 4 holes diam 10mm and fix the AC reactor with the included bolts and nuts Make sure that no burs from the drilling can enter the frequency inverter or other components www groupdynamics laundry com sales groupdynamics lv ...

Страница 8: ...525928 Instruction AC reactor FS16 55 RS27 35 P8 15 Make the electrical connection according the scheme and instructions below www groupdynamics laundry com sales groupdynamics lv ...

Страница 9: ... AC reactor 3 ph inverter Connect these wires to terminals U1 V1 and W1 of the AC reactor 1 ph inverter Connect terminals U2 and V2 to the inverter contactor by new wires to the same terminals where you have disconnected the 2 other wires Terminals W1 and W2 of the AC reactor will not be used if the inverter is 1 phase 3 ph inverter Connect terminals U2 V2 W2 to the inverter contactor by new wires...

Страница 10: ...ctor on a suitable place in the electrical box at the back of the machine Drill 4 holes diam 10mm and fix the AC reactor with the included bolts and nuts Make sure that no burs from the drilling can enter the frequency inverter or other components www groupdynamics laundry com sales groupdynamics lv ...

Страница 11: ...525928 Instruction AC reactor FS16 55 RS27 35 P11 15 Make the electrical connection according the scheme and instructions below www groupdynamics laundry com sales groupdynamics lv ...

Страница 12: ...U1 V1 and W1 of the AC reactor You migth have to replace the original wires by longer ones Connect terminals U2 V2 W2 to the inverter contactor input side by new wires to the same terminals where you have disconnected the 3 other wires Make sure to attach and connect all wirings so that they can not be damaged by vibrations www groupdynamics laundry com sales groupdynamics lv ...

Страница 13: ... the corner of the back panel but it has the small disadvantage that you always need to disconnect the wires if you want to open the back panel Drill 4 holes diam 10mm and fix the AC reactor with the included bolts and nuts Make sure that no burs from the drilling can enter the frequency inverter or other components www groupdynamics laundry com sales groupdynamics lv ...

Страница 14: ...525928 Instruction AC reactor FS16 55 RS27 35 P14 15 Make the electrical connection according the scheme and instructions below www groupdynamics laundry com sales groupdynamics lv ...

Страница 15: ...and W2 of the AC reactor will not be used if the inverter is 1 phase 3 ph inverter Connect terminals U2 V2 W2 to the inverter contactor by new wires to the same terminals where you have disconnected the 3 other wires Make sure to attach and connect all wirings so that they can not be damaged 5 Remarks If you have a machine with a transformer for the control circuit this transformer fulfills the sa...

Отзывы: