525928 Instruction AC-reactor FS16-55 RS27-35
P15/15
1-ph inverter (standard version):
Disconnect the 2 wires (normally blue and black)
from the mainswitch that go to the filter.
3-ph inverter (3x380-480V without N only):
Disconnect the 3 wires (normally black) from the
inverter contactor (CFI) that come from the
mainswitch.
1-ph inverter :
Connect these wires to terminals U2 and V2 of
the AC-reactor.
3-ph inverter :
Connect these wires to terminals U1, V1 and W1
of the AC-reactor.
1-ph inverter :
Connect terminals U1 and V1 of the AC-reactor
to the mainswitch by new wires, to the same
terminals where you have disconnected the 2
other wires.
Terminals W1 and W2 of the AC-reactor will not
be used if the inverter is 1-phase.
3-ph inverter :
Connect terminals U2,V2,W2 to the inverter
contactor by new wires, to the same terminals
where you have disconnected the 3 other wires
Make sure to attach and connect all wirings so
that they can not be damaged.
5) Remarks:
If you have a machine with a transformer for the control circuit, this transformer fulfills the same protection
function as the AC-reactor. It means that the AC-reactor is only necessary in the circuit of the inverter, it is not
necessary to put the AC-reactor also in the circuit of the control circuit (but it is allowed).