5-1 Hybrid System Wiring
Fig. 11
represents a typical “hybrid”
system with solar panels. Some charg-
ing sources (solar panels, fuel-powered
generators, additional wind generators,
etc.) connected to the same system
may cause interference with the Air X
internal electronics and result in pre-
regulation. The interference will not
harm the turbine; it will just cause it to
spin slowly as if “braked” or it may stop
the turbine. If this occurs, test for pos-
sible interference by disconnecting the
other charging sources to determine
the possible cause. If possible wire the
turbine and PV panels to their own set
of battery posts.
TIP:
In this figure the Air X
internal regulator is used. A
diversion type external regulator
could also have been used.
TIP:
Voltage “pre-regulation”
may be prevented by increasing
the regulation set point. See
section 7-3-2.
Air X
TIP:
batteries wired in series and
Battery bank illustrated
is configured as four 6-volt
bank configuration and system
voltage are site specific.
=