938 Quail Street
Lakewood, CO 80215
primuswindpower.com
Pg.1/5
PWP Wind Control Panel Manual 2 -ARAC-103
Wind Control Panel Instruction Manual
(for use with AIR Breeze and AIR 40 12V turbines)
The wind control panel is fully calibrated and ready for
installation. Please follow the instructions below for proper
installation.
P/N VOLTAGE BREAKER
AMMETER
2-ARAC-103 12 VDC 160 W TURBINE 25A
15
2-ARAC-104 24 VDC 160 W TURBINE 10A 8
2-ARAC-107 48 VDC 160 W TURBINE 5A
8
2-ARAC-108 12 VDC 400 W TURBINE 40A
30
OVERVIEW:
The POWER switch is used to turn the wind turbine control panel on and off as well as provide
protection in the case of a major fault. The STOP-RUN toggle switch controls the operation of the
wind turbine. In the RUN position, it allows the wind turbine to operate and produce power while
in the STOP position it places an electric brake on the wind turbine spindle stopping the rotation (in
this mode, slight blade rotation may occur in strong winds). The center position is an OFF position
(disconnecting the wind turbine), but is not recommended. The Ammeter monitors the wind
turbines production.
The wind control panel should be connected to a wind turbine with a current rating equal to or less
than the panel's rating. The Air Breeze and Air 40 units have built-in battery charge regulators. If a
wind turbine is utilized that does not have a built-in regulator, an external diversion load controller
will be necessary to provide proper protection from over charging the battery bank.
Warning
Disconnect battery(s) prior to making connections. Secure the rotor blades of the wind turbine
mechanically so that it is unable to rotate.