120 VAC Wiring & Power Specifications
120 VAC Wiring Requirements
Levo Series Digital Clocks/Timers are shipped from the factory with a power supply and power cord with a two prong plug.
The power plug may be removed and cord cut to length for hardwired (pigtail) installation. Pigtail installation requires a 120V~
power line in a junction box installed by a licensed electrician. Leave a minimum of 6 inches (15 cm) of cord inside the junction
box.
120 VAC Power Requirements
Clock Type
Weight
Max. Current Draw
Height (A)
Width (B)
Depth (C)
2.5" (6.4 cm), 6-digit
2.0 lbs. (0.9 kg)
230 mA
5.0" (12.7 cm)
13.75" (34.9 cm)
2.2" (5.6 cm)
2.5" (6.4 cm), 4-digit
1.8 lbs (0.8 kg)
170 mA
5.0" (12.7 cm)
10.8" (27.4 cm)
2.8" (5.6 cm)
4" (10.16 cm), 4-digit
3.9 lbs. (1.8 kg)
240 mA
8.0" (20.3 cm)
17.9" (45.5 cm)
2.4" (6.1 cm)
4" (10.16 cm), 6-digit
4.6 lbs (2.1 kg)
260 mA
8.0" (20.3 cm)
2.3" (59.3 cm)
2.4" (6.1 cm)