Primex OneVue Sense A100 Скачать руководство пользователя страница 11

It's recommended that the device is in a clear line of sight to a wireless access point. If the location is NOT in a clear
line of sight to a wireless access point, its LCD screen must be above the unit it's being mounted to.
Wireless signal strength of -60db or better at the mounting location. It's recommended to measure the strength with
a Wi-Fi analyzer app on a mobile phone.

• PoE/Ethernet use

An open, active network port in close proximity to the mounting location.

• AC power

Outlet within 5 ft. (1.5 m) from its mounting location. Devices using AC or PoE power can also use battery power as a
backup power source in the event of a power loss. During battery backup, the device operates on battery power and
continues to log and transmit readings until the primary power source is restored.

CAUTION

The device is shock and vibration resistant; however, be careful not to drop or install the device in a
location where it could be exposed to excessive vibration.

Step 1: Verify sensor configuration

Prior to installation, a sensor device must be configured for use with OneVue. A sensor is either configured prior to
shipment through Device Preconfiguration or onsite using the OWDC app.

• Device Preconfiguration completed: white label with configured settings is affixed to the backside of the sensor.

Sensor has been configured with network settings allowing its connection to OneVue and also added to OneVue.
Proceed to next install step.

• OWDC onsite configuration required: Sensor shipped with factory default settings and is not added to OneVue.

You must configure the sensor now using the OWDC app.

Step 2: Insert sensor batteries and turn on battery power

1. Remove device cover; simultaneously press the two tabs located on the top side of the device (A).
2. Insert the 3.0v Primex Lithium/Iron Disulfide Battery Pack or two 1.5v Lithium AA batteries. Follow the symbols

showing the correct way to position the positive (+) and negative (-) ends of the battery pack.

3. Located to the lower-right of the battery compartment, set the battery on/off switch to the Up (On) position (B).
4. Replace the device cover.

Page 11

Содержание OneVue Sense A100

Страница 1: ...OneVue Sense Temperature and Humidity Sensor Installation Guide Product Models A100 09 25 19 ...

Страница 2: ...property of their respective owners The Bluetooth word mark and logos are registered trademarks owned by the Bluetooth SIG Inc and any use of such marks by Primex Inc is under license Primex is the leading provider of solutions to automate and maintain facility compliance increase efficiencies enhance safety and reduce risk for enterprise organizations in the healthcare education manufacturing and...

Страница 3: ...eVue 8 Install Temperature and Humidity Sensor 10 Supplied components 10 Mounting guidelines 10 Step 1 Verify sensor configuration 11 Step 2 Insert sensor batteries and turn on battery power 11 Step 3 Mount sensor 12 Step 4 Establish connections 13 Step 5 Verify connection to OneVue 13 Step 6 Verify OneVue settings 13 OneVue Network Requirements 15 Network communication protocols 15 Safety Regulat...

Страница 4: ...ded Estimated Battery Life Up to 18 months with use of Lithium 1 5V batteries estimation based on 1 hour Logging Interval 8 hour Check In Interval and adequate wireless signal Network Communication Wireless Networking Protocols 802 11b 11g 11n single stream 2 4 GHz Wireless Security Protocols WEP Open Shared WPA TKIP AES WPA2 TKIP AES Wireless Authentication Protocols None EAP FAST EAP TLS EAP TTL...

Страница 5: ...nd its readings will return to normal after the moisture evaporates NEVER spray cleaning fluid directly on the unit Moisture in the spray will spike the RH reading Temperature and Humidity Sensor device features The below image represents the components of a OneVue sensor device Temperature and Humidity Sensor LCD display The LCD display of a OneVue Temperature Humidity Sensor provides a visual re...

Страница 6: ...timated battery life remaining is 30 days This estimation is based on the use of lithium 1 5V batteries 1 hour Logging Interval 8 hour Check In Interval and adequate wireless signal If the device is powered by AC or Power over Ethernet PoE the yellow LED indicator flashes during this state Lbat The device is an Alarm state due to its battery level is critically low Readings are not logged or trans...

Страница 7: ...e LED State Status Device power Green LED illuminated Normal state Operating as expected AC or PoE power LED illuminated Battery power only LED disabled to conserve battery life Upon power up illuminates for 2 seconds Yellow LED flashing Warning state Low battery Unresponsive AC or PoE power LED illuminated and flashes Refer to the LCD display to identify the condition Red LED flashing Reading Ala...

Страница 8: ...ery power use only When operating solely on battery backup power estimated battery life is 7 days This estimation is based on the use of Lithium 1 5V batteries 1 hour Logging Interval 8 hour Check In Interval and adequate wireless signal Use of alkaline batteries is not recommended Power over Ethernet PoE Temperature Temperature and Humidity Differential Pressure Water Leak and Contact Closure Sen...

Страница 9: ...he device s non volatile memory If the number of failed check ins exceeds the size of the non volatile memory the oldest readings are overwritten Primex sensor devices store up to 4096 readings If you only hear 1 beep The device could not connect to the facility s network Contact the onsite IT department to seek assistance to determine why the device failed to connect to the network It s recommend...

Страница 10: ...a wall at eye level similar to a thermostat For an overall humidity reading for a room it s important to install in a location that will not be exposed to hot humid air that may skew the results For example don t install next to a piece of equipment that may exhaust hot air or near a scrub sink where hot water can give off steam Device is designed to be mounted on a wall Lying a device on a counte...

Страница 11: ...e vibration Step 1 Verify sensor configuration Prior to installation a sensor device must be configured for use with OneVue A sensor is either configured prior to shipment through Device Preconfiguration or onsite using the OWDC app Device Preconfiguration completed white label with configured settings is affixed to the backside of the sensor Sensor has been configured with network settings allowi...

Страница 12: ...he wall surface 1 75 in 4 4 cm distance between the two screw slots 2 Insert wall anchors 3 Remove device cover to attach the device to the wall surface by inserting 6 drywall screws Ensure the device is properly secured and level A B Surface mount 3M Dual Lock Fastener Tape 2 x 1 strips 1 Prepare the mounting area to ensure maximize adhesion If there is moisture dry the area first 2 Press a black...

Страница 13: ...Vue settings Verify the following settings are configured to meet the requirements of the condition being monitored 1 Monitored Asset settings Go to Monitoring Monitored Assets Each Primex sensor device is assigned to a Monitored Asset and its readings or monitored conditions generate the Monitored Asset s current and historical readings In addition sensor operating condition data is linked to its...

Страница 14: ...hat is activated during a reading Alarm state Out of Range Past Alarm Delay status The audio alert is activated when a reading is out of range and the time period it has been out of range has exceeded the time period set in its Alarm Delay Logging Interval sensor gateway setting The Logging Interval is how frequent a sensor logs a reading and stores it into its internal memory All logged readings ...

Страница 15: ... PEAP v1 GTC Network Communication Protocols Hypertext Transfer Protocol Secure HTTPS TLS 1 2 IP Addressing Dynamic Host Configuration Protocol DHCP static IP addressing Data Packet Size typically less than 5 kilobytes kB Power over Ethernet PoE and Ethernet supported specifications Applies to OneVue Temperature Sensor Differential Pressure Sensor Water Leak Sensor Contact Closure Sensor OneVue Sy...

Страница 16: ...t may change IP addresses at anytime therefore OneVue does not support the use of firewall IP address filtering If firewall supports wildcards Domain filters URL filters primexonevue com us east 1 production s3 amazonaws com https primexonevue com https us east 1 production s3 amazonaws com If firewall does not support wildcards Domain filters URL filters console primexonevue com deviceapi alt pri...

Страница 17: ...ges not expressly approved by Primex might cause harmful interference and void the FCC authorization to operate this product FCC Radio Frequency Interference This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential inst...

Страница 18: ...t or relocate the receiving antenna l Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be instal...

Страница 19: ...n any way including but not limited to attempted warranty repair other than by Primex or an authorized service partner Limitation of Liability The warranties and remedies contained herein are exclusive and in lieu of all other warranties express or implied or statutory including any liability arising under any warranty or merchantability or fitness for a particular purpose implied statutory or oth...

Страница 20: ...er technical support services for Primex products If you have purchased Primex products or have a service agreement with a Primex Partner they are your primary contact for all Technical Support inquires When contacting Technical Support Make sure you have satisfied the system requirements specified in the product documentation Also be at the computer or device on which the problem occurred in case...

Отзывы: