![Primes CUBE Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/primes/cube/cube_operating-manual_1601732013.webp)
35,0(6
Cube
13
Revision 01/2019 EN
7.3
Install the Cube
1.
Align the device with the laser beam as described in chapter 7.2 on page 11
and Fig. 7.1 on page 12.
2.
Install the device to the mounting threads as shown in Fig. 7.2 on page 13.
3.
Ensure a stable installation of the device:
•
The device must not be able to move.
4.
Connect the safety interlock connection cable.
5.
Remove the protective foil from the protective window of the device.
M6 x 6
2x
M4 x 8
50
5
5
10
Fig. 7.2:
Mounting threads in the Cube housing
7.4
Remove the Cube
1.
Turn off the laser source.
2.
Ensure that moving parts, e.g. robot arms, etc. are at a standstill and that they
cannot be set in motion unintentionally.
3.
Unscrew the mounting screws from the mounting threads (see Fig. 7.2 on
page 13).
4.
Remove the safety interlock connection cable and remove the device from the
laser system.
5.
Apply the protective foil to prevent contamination of the protective window.