Check point before A/S

In these symptoms

Take measures like this

There is

no power supplied 

in the machine.

Buttons are

not working

There is a message of

Over Temperature.

There is a connection

error message.

Letters in the monitor

has a problem.

 Check the other machines to check black out

 Check the power plug connecon

 Check the power switch on

 Check the disconnecon of the fuse in the fuse box rear part of the product. 

      If the fuse is disconnected you should replace it.

 Open the external case to check connecon of 2 cables from the monitor.

 Open the external case to check connecon of Fan Connector.

 Open the external case to remove foreign materials in fan wings.

 If the Fan does not work aer those measures, please change the fan. 

     Fan is an expendable.

 Check the shade temperature if the temperature is high cooling it and try again.

 Work aer connect the baery and the machine.

 Check the baery voltage. Baery is not working below 30% of standard voltage.

 Reconnect aer clean the sockets.

 Check the connecon of polarity.

 Open the external case to check connection of display board attached from

      monitor and switch board.

 If the switch is not working that can be inner switch problem so contact to

      our customer service for A/S. (2 year warranty)

 Open the external case and reconnect grey Flat Cable connected to 

      display board.

Before you have A/S you should check those things
If you have A/S in these things sum of money would be asked.

If the problem is not solved after those measures,

contact our customer service to get the solution.

Warranty : 

Two years limited & condioned warranty would be supported. If you have any trouble with PRIME products, we will send instrucon 

manuals with pictures for disassemble & assemble guide case by case.

    

Aer Service Commitment :

 

If you have any defecve maer with PRIME products, you should inform us of its symptom with pictures or video earlier to return.  

If we determine that it should be repaired or replaced, then you should disassemble a board to be dispatched via an express mail 

service.   Or, we will send some parts via DHL for replacement by your technician.  The free warranty will be covered for all defecve

maers without any defects by misuse.  Of course, we will pay for all return internaonal freight cost for replacement or repair 

during one year limited free warranty period.   Aer One Year ~ Two years – we will supply for the consuming of troubled consuming

parts with a collect DHL freight cost. 

Содержание BASIC RPT-T300

Страница 1: ...ual well not to get lost Please don t reprint or copy the image and the words because Repowertek Inc in Korea reserve all the copyrights of the contents to be used in this manual The exterior design a...

Страница 2: ...ying intelligent smart control system with high frequency Pulse Technology to get the best possible charging of used batteries expecially car batteries This product is only for 6V 8V and 12V batteries...

Страница 3: ...let It can cause an electric shock a fire Connect the cord of the power plug down Don t pull the electric cord electric wire when you unplug the power Otherwise in case of connecting it when the wire...

Страница 4: ...can be caused Please take notice Please surely get rid of the metallic necklace and chain a bracelet other accessories on the body in case of the operation of regeneration and charge When the short c...

Страница 5: ...n ow of the product should be prohibited thoroughly Input the same value as the specification of a battery at the moment of the set up Please check the specification of the battery on the exterior of...

Страница 6: ...using the optimized high frequency pulse Optimized Automatic Regeneration Charge Algorithm It can be used in all types of lead acid battery by adjusting specialized automatic regeneration charge algo...

Страница 7: ...atically START STOP Button When you push START STOP button the machine starts its work after inputting set value of battery voltage current and time is finished If you push START STOP button in workin...

Страница 8: ...yed automatically in After part These are regenerated or charged battery conditions After Message Work progress indication and warning message are displayed Refer to the below items Run Time H M Regen...

Страница 9: ...layed right part of LCD indicator after pushing ENTER button more than 2 seconds The displayed value in upper line is IR one and the lower line is CCA one This function cannot be worked during regener...

Страница 10: ...values are displayed right part of LCD indicator after pushing ENTER button more than 2 seconds The displayed value in upper line is IR one and the lower line is CCA one This function cannot be worke...

Страница 11: ...ause You can start the work by pushing START STOP button in front part of the machine after input 1 4 topic is completed and check the Internal Resistance and CCA measure of before regeneration You ca...

Страница 12: ...7 RC Reserve Capacity value display The elapsed discharge time is displayed in Run Time H M in WORK part after started discharge The elapsed discharge time means RC Reserve Capacity value that is the...

Страница 13: ...planation Ex 12V 100Ah Battery RegenerationWork Control Button SELECT Button LCD Indicator SET SET or Battery Condition Test Input way of Condition Test Identification set value This is a Damage Ident...

Страница 14: ...C Voltage CCA Internal resistance CASE 2 CASE 1 CASE 3 CASE 4 PRIME charging voltage is going to 13V within about 40 minutes KEEP to Regenerate OK Test Finish PRIME charging voltage is not going to 13...

Страница 15: ...lectric forklift golf cart tower wagon and so on which using lots of electricity In these days industrial UPS battery is using Deep cycle method to supplement low priced industrial lead storage batter...

Страница 16: ...board If the switch is not working that can be inner switch problem so contact to our customer service for A S 2 year warranty Open the external case and reconnect grey Flat Cable connected to display...

Страница 17: ...epair of others without Repowertek Inc technicians When performance and func onal trouble occurred in reten on period under the normal using Clean adjust using explana on and setup except machine trou...

Страница 18: ...NF SFQPXFSUFL DPN is REPOWERTEK INC Regenerator Discharger Brand All products of REPOWERTEK INC in manufacture and production directly from South Korea BEF JO PSFB 2F Tosung Plaza 55 10 Gilju ro 77beo...

Отзывы: