1.
Function(Mode) set-up
Set up part.
ⴜ
of the LCD indicator changed or designate to CONDITION TEST by pushing
ⵐ
SELECT
button in the front part of the machine.
2. Nominal battery voltage set-up
This mode is a 12V battery only. Thus it is fixed to 12V.
3. Input battery capacity
Designate the showed exterior battery capacity to 100.0 by using
ⵒ
UP button and
ⵓ
DOWN button when
the arrow(
ⶺ
) located in the Capacity (Ah) / Current (A) of part.
ⴙ
.
4.
Internal resistance / CCA values measure
Refer to “4. Internal Resistance / CCA value measure” in “Regeneration Mode” of
previous page.
5. Start of pause of regeneration
You can start condition test work by pushing
ⵔ
START / STOP button after input Capacity (Ah) /
Current (A) in part.
ⴙ
and check IR and CCA values of before condition test.
You can pause condition test work by using
ⵔ
START / STOP button during the work.
6.
Progress condition display
After started condition test supplied voltage is displayed in
ⴘ
Battery Voltage / CV under the
WORK part in real time and the hourly supplied current is displayed in
ⴙ
Capacity (Ah) / Current (A).
ⴚ
Run time(H:M) is elapsed work time is displayed under the WORK part.
7.
Message Type Contents Explanation
Ex) 12V / 100Ah Battery Regeneration Work
Control Button
SELECT Button
LCD Indicator
SET
SET
or
Battery Condition Test
Input way of Condition Test
(Identification)
set value
This is a Damage Identification Message there is cell corrosion more than 1cell in battery.
(Bad Battery)
This is a Damage Identification Message that there is cell short more than 1cell in battery.
(Shorted Circuit Battery)
This is a Damage Identification Message that there is cell cut more than 1cell in battery.
(Bad Battery)
This message appears when the battery voltage is less than DC 8V. Please retest after charge.
(Check Battery)
This message appears when the battery voltage is more than DC 16V. This mode 12V battery only.
This message is displayed when there is no battery voltage, the +, - terminals are connected to the
battery differently, and one or both clips are disconnected due to external shock in machine working.
This is a message that the battery is possibly identified as to be regenerated or charged battery by finishing
Identification ordinarily.
*
Prior to the ‘
CONDITION TEST
’, all 12V batteries should be charged to
over 9V
at least. Please use a conventional
charger for this recharge. (If a low voltage battery is not charged well, use a ‘Power Supply’ mode of PRIME)
- Most batteries lower than 11V will be cell corrosion states. – Limited capacity