background image

 

12

CONTROLLER DIMENSIONS 

 
 

 

 
 

LIMITATION AND EXCLUSION OF WARRANTIES 

 

All goods purchased form PRIME CONTROLS, INC. shall be free from defects in 
materials, design and workmanship under normal conditions of use for one year from 
the date of shipment.  THIS WARRANTY IS THE SOLE WARRANTY AND IS 
EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, 
INCLUDING BUT NOT LIMITED TO ANY IMPLIED, WARRANTY OF 
MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE.  THE LIABILITY 
OF PRIME CONTROLS TO ANY PURCHASER SHALL BE LIMITED EXCLUSIVELY 
TO THE COST OF REPLACEMENT OR REPAIR OF DEFECTIVE PARTS, AND 
SHALL NOT INCLUDE LIABILITY FOR ANY DIRECT, CONSEQUENTIAL OR 
INCIDENTAL DAMAGES WHATSOEVER, WHETHER FORESEEN OR 
UNFORESEEN, INCLUDING BUT NOT LIMITED TO LOST PROFITS, LOST SALES, 
OR INJURY TO PERSONS OR PROPERTY 

(Pico Style)

 

Содержание FLUXIMITY DS71

Страница 1: ...ers are explained is this instruction sheet The Fluximity system includes a microcontroller based control module in a 18mm threaded aluminum housing The Controller is connected to a family of magnetic...

Страница 2: ...ule Installation The DS71 72 Controller module is designed to mount with a simple bracket where convenient between the probe and a higher level controller such as a PLC Avoid mounting locations with e...

Страница 3: ...t a location where the maximum field is not blocked may cause false doubles During production the metal may move to a point where more flux is covered This is especially true when the shape of the bla...

Страница 4: ...rmal indicator colors are covered on page 8 If the magnetic field signal is strong the multi function indicator will be off this assumes the probe face was mounted within 50mm of the magnetic conveyor...

Страница 5: ...ignal The Fluximity operates best if the magnetic strength is 100 gauss Gauss G is a unit of measurement for magnetic field strength or flux density For example approx 1 gauss from earth s magnetic no...

Страница 6: ...econds elapses with no press of the pushbutton The detector has a standby calibration feature that permits calibration while the metal is moving Press the pushbutton once with no metal between the mag...

Страница 7: ...thickness of the two samples is too close for reliable gauging the indicator flashes amber at a 10 Hz rate for up to 15 seconds or until the pushbutton is pressed again After 15 seconds it returns to...

Страница 8: ...ber and then begins flashing red rapidly 10 Hz This can indicate a there is metal present b the probe is disconnected or c the cable to the probe has an open or d the probe is faulty During Single Hit...

Страница 9: ...FIRMWARE VERSION The format of the firmware version number is of the form 1 2 comprising a single digit integer part and a single digit fractional part When first powered up the controller displays t...

Страница 10: ...ection 12 mm Connector Pin 4 Max source current 50mA fuse limited Output Voltage High Supply Voltage less 1 volt Over current protection Self resetting thermal fuse ESD protection Transient Voltage Su...

Страница 11: ...11 DS71 DRIVE CIRCUITRY CONTROLLER 30V 30V 30V 2 1 4 3 50 mA 50 mA V COM SINGLE NO DOUBLE DS72 DRIVE CIRCUITRY CONTROLLER 30V 30V 30V 2 1 4 3 50 mA 50 mA V COM SINGLE NO DOUBLE...

Страница 12: ...F ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE THE LIABILITY OF PRIME CONTROLS TO ANY PURCHASER SHAL...

Отзывы: