background image

performance of the tool. Pay special attention to any air leaks. Do
not use a compressed air pressure higher than 110 psi (7.6 bar).
Higher pressure can cause premature wear or damage to certain
components.  After  assembly,  check  all  the  connections  to
prevent the leaks and to have maximum efficiency.

T

O PREVENT ACCIDENTAL DAMAGE TO THE FINISHED

SURFACE OF THE INSTALLED FLOOR

,

 REST THE TOOL

ONTO THE SUBFLOORING WHEN CONNECTING AIR

,

LOADING TOOL WITH NAILS OR PERFORMING ANY
MAINTENANCE TO THE TOOL

.

LOADING THE TOOL

Insert a row of P

RIMATECH

's cleats inside the feeder channel and

pull  back  on  the  plastic  tab  gently  until  it  engages  behind  the
cleats. To release, simply squeeze the tab with your thumb and
index  and  allow  the  spring  to  recoil  slowly.  The  clip  must  be
released slowly to prevent damage. The Q550 uses standard 

L

-

type  18

GA

  cleats  available  in  lengths  of  1¾"  (45  mm),  1½"

(38 mm) and 1¼" (32 mm). Make sure that the proper type of
cleats is used. Primatech's 18

GA

 cleats are packaged into green

color-coded  boxes.    For 

MAXIMUM  PERFORMANCE

,  always  use

P

RIMATECH

 cleats.

U

SE ONLY THE TYPE OF CLEATS IDENTIFIED ON THE

FEEDER CHANNEL

.

 

T

HE USE OF ANY OTHER TYPE OF

CLEATS WILL DAMAGE THE TOOL

.

OPERATION

Unload tool and rest it onto the subflooring, Connect the hose
and cycle tool once or twice without nails. After loading the tool
with  P

RIMATECH

  cleats,  the

  PNEUMATIC  NAILER

  model  Q550  is

ready for use.

Only use the 2.5 lbs (1.1 kg) hammer supplied with the tool. The
use  of  other  type  of  hammers  may  affect  performance.  The
rubber face of the hammer can be used with care to help position
the boards.

With the flooring firmly in place, position the tool onto the flooring,
with the resting block Q-034 against the tongue. Apply downward
pressure to ensure proper seating of the cleat. Strike the head
cap Q-001 with the hammer to activate the tool,

Use only the 

RUBBER FACE

 of the hammer to

activate  the  tool.  Using  the  steel  end  will
damage  the  tool  and  void  the  warranty.

  If

wood is slightly twisted, hitting the tool with more
force will assist in pulling the board up snugly.

NEVER

 strike the head cap when the tool is not

sitting on the working surface.

O

PERATING THE TOOL WHEN THE SAFETY CONTACT IS

NOT FULLY DEPRESSED WILL CAUSE PREMATURE WEAR
OR DAMAGE TO THE DRIVING BLADE

,

 PISTON AND

CYLINDER

.

Eye protection is recommended and should be
worn by the operator and other in working area.
Accidental ejection of nails or wood debris could
cause severe eye injury.

In some environments, ear protection might be
required, as working condition may include
exposure to high noise levels which lead to
hearing damage.

Wearing  safety  boots  and  safety  hat  is  also
highly recommended.

N

OTE

:  All  the  personal  protection  equipments

must meet national standards.

Be  it  raw,  factory  finished  or  engineered,  hardwood  is  a
natural material subject to various factors, such as humidity,
subflooring, installation procedure, type of tools, fasteners,

etc

.  Installer  should  always  ensure  optimal  surface

preparation,  com ply  with  all  manufacturer's
recommendations  and  conduct  a  pre-installation  test  prior
beginning any installation.

B

EFORE STARTING AN INSTALLATION

,

 FASTEN DOWN

FEW BOARDS TO ASCERTAIN THAT YOU ARE USING
THE RIGHT FASTENER AND THAT THE TOOL IS
PROPERLY ADJUSTED

.

ADJUSTING FOR HARDWOOD THICKNESS

The Q550 pneumatic nailer is fitted with a fully adjustable plastic
base Q-033, designed to prevent contact with the top edge of the
flooring. Since there is no standard among manufacturers about
the dimensions of the tongue, it is important to adjust the nailer
to fit the flooring prior any installation. The Q550 also features a
resting block Q-034 which prevent damage to the top edge of the
flooring by positioning the tool against the tongue, preventing the
gate/foot assembly from contacting the board.

Step 1: adjusting the base for flooring thickness:

Using the supplied Allen wrench, loosen but do not remove
screws (A); one on each side of the tool.

With the tool in an upside down position, place a short piece
of flooring against the gate/foot assembly (Q-029/Q-032).

Engage  the  Allen  wrench  in  knob  (B)  as  shown;  rotate  to
move the base up or down. Note that knob (B) has a rotation
range of only about 1/2 turn. Do not apply force when a limit
is reached.

Adjust the height of the plastic base to obtain a small gap
between  the  gate/foot  assembly  and  the  top  side  of  the
tongue of the sample board. A gap of 1/32", about half the
thickness of the nail, should be adequate for most situations.

Tighten both screws (A).

Содержание Q550

Страница 1: ...Revision 03 10 Printed in Canada PNEUMATIC FLOORING NAILER Q550 OPERATING INSTRUCTIONS WARNING Read these instructions thoroughly before using this tool and keep it handy for reference ...

Страница 2: ... tool clear obstructions or make adjustments while the air supply hose is connected 10 Only compressed air should be used to power this tool do not exceed 110 psi 7 6 bar 11 Never use oxygen or any other compressed gas as a power source for this tool 12 Always wear OSHA required Z 87 safety glasses with side shields 13 Always wear proper ear and feet protection while the air supply hose is connect...

Страница 3: ...e OPERATING THE TOOL WHEN THE SAFETY CONTACT IS NOT FULLY DEPRESSED WILL CAUSE PREMATURE WEAR OR DAMAGE TO THE DRIVING BLADE PISTON AND CYLINDER Eye protection is recommended and should be worn by the operator and other in working area Accidental ejection of nails or wood debris could cause severe eye injury In some environments ear protection might be required as working condition may include exp...

Страница 4: ...re tight Pay particular attention to the two screws holding the feeder channel as well as the screws and nuts on the feeder channel assembly who might loosen up over time Be careful not to strip the threads when tightening The use of an medium strength adhesive sealant such as the Loctite 242 is recommended for those screws and nuts MAINTENANCE REPAIR Most adjustments to the tool can be made with ...

Страница 5: ...SSEMBLY 8 Check that the piston sub assembly including rings and driving blade is sliding easily into the cylinder Q 018 It should offer some resistance but if it moves too easily it may be required to replace the piston wear ring Q 022A 9 Insert the seal bushing Q 025B in the lower section of main body Q 006 and engage it onto the upper portion of the gate foot assembly Q 029 Q 032 A flat screwdr...

Страница 6: ...of the tool 2 Pull out the piston assembly from the cylinder Remove any debris and assess condition of cylinder Q 018 If marked or grouged use a fine sand paper to smooth out walls The piston Q 022 must be allowed to move without restriction 3 Insert the piston sub assembly into the main body Q 016 and engage the driving blade Q 023 in the seal bushing opening Depress the safety contact Q 062 to e...

Страница 7: ...t end of the feeder channel for burrs or damages d Check the safety mechanism e Check if the driver is stuck in down position see 6 below f Check for obstruction in the cleat ejection area 4 CLEATS ARE NOT SET COMPLETELY a First verify air supply see 1 above b Clean tool and lubricate tool particularly the head assembly c Increase air pressure when working with harder woods do not exceed 110 psi 7...

Страница 8: ...position the jack on the floor or in the field of flooring without damage to the flooring enabling hands free operation for nailing OTHER PRIMATECH NAILERS PRIMATECH offers a full line of professional tools for the installation of hardwood flooring Standard models for 5 8 to 33 32 solid flooring 16 26 mm H300 Single Hit manual nailer H330 Multiple Hits manual nailer P240 pneumatic nailer P250A Pri...

Страница 9: ...ushing Q 025 Pare chocs bague d étanchéité Foot Q 029 Plaque Gate Q 032 Plaque guide Adjustable plastic base Q 033 Semelle ajustable Resting block Q 034 Bloc d appui Bracket Q 034A Équerre Brackets Q 035 A B Équerres Cam axle Q 036 Axe des cames Left cam Q 036A Came gauche Right cam Q 036B Came droit Actuator Q 042 Déclencheur u cup seal Q 042A Joint rectangulaire Valve Q 043 Valve Actuator cap as...

Страница 10: ...ONNECT AIR SUPPLY WHEN ADJUSTING SERVICING OR DISASSEMBLING THE TOOLS ATTENTION POUR ÉVITER TOUT RISQUE DE BLESSURE TOUJOURS DÉCONNECTER L ALIMENTATION EN AIR COMPRIMÉ LORS DE L ENTRETIENT OU DU DÉMONTAGE DE L OUTIL IMPORTANT REFER TO THE INSTRUCTIONS MANUAL AND READ THE SAFETY MEASURES SECTION BEFORE USING OR SERVICING TOOLS IMPORTANT RÉFÉRER À LA NOTICE D UTILISATION ET LIRE LA SECTION CONSIGNES...

Страница 11: ......

Отзывы: