Flush Channel Installation Guide
2
v001 | Flush Channel Installation Guide
Product Overview
The Node Flush Channel assembly consists of two mounting angles held together by intermittent mounting brackets,
which interface with the channel face.
The Node Flush Channel is designed to be installed between ceiling panels or plasterboard, in ceilings with recessed
voids.
The following guide should only be used for Node Flush Channel where PARC is not providing the diffuser or plenum.
Please refer to our Node Flush Channel with Diffuser Installation Guide if you are installing with the Node with Diffuser.
It is recommended that the Node Flush Channel length is coordinated with the manufacturer to the required sizes to
match the building design. The Node Flush Channel can be site cut if required.
The Node devices are supplied separately from the channel assemblies.
Note:
All mounting hardware and sub structure is to be supplied and installed alongside the Node Flush Channel.
Lighting and other services must be installed by qualified personnel.
For further information regarding product or installation, please contact
.
Figure 1
9.84
250
OVERALL WIDTH
3.57
91
CHANNEL HEIGHT
4.72
120
EXPOSED WIDTH
.23
6
RECOMMENDED CLEARANCE
W/ SURROUNDED CEILING
Flush Channel with Weave Panel
4.72
120
FACE WIDTH
.40
10
.12
3
RECOMMENDED CLEARANCE
W/ SURROUNDING CEILING
11.81
300
OVERALL WIDTH
4.16
106
CHANNEL HEIGHT
Flush Channel with Soft Cell Panel
Flush Channel with Weave Panel
Flush Channel with Soft Cell Panel