background image

Function:

The RCI-200-RF2 is a bi-directional data communication
system that exchanges the status of 2 dry contact inputs
and 2 analog inputs between a master and one or more
remote units. A basic system consists of one master
station and one remote station each with 2 dry contact
and 2 analog inputs and 2 'C' relay contact and analog
outputs. All signals are bi-directional so that data may be
read from the remote station and sent to it.

The license-free spread-spectrum radio technology
allows small systems to be set up with very little effort and
at low cost.

The technology ensures high

communication reliability even in RF-intensive
environments.

All units are sold without antennas. Pribusin carries a
complete assortment of antennas and accessories.

Options:

- A: 24VDC Power
- B: 240VAC Power
- N12: NEMA 12 Enclosure

Standard Features:

Bi-directional Communication using License-free
2.4GHz Radio Band

Spread-Spectrum Radio Technology Provides
Reliable Communication

2 Dry Contact and 2 Analog Inputs

2 'C' Relay Contacts and 2 Analog Outputs

Point-to-Point or Host-to-Multipoint Topologies

No Calibration Required

Microprocessor Controlled for High Accuracy

Power: 117 VAC 50/60 Hz (Optional 24 VDC)

High Noise Rejection

CSA and NRTL Approved (LR51078)

Re-Transmission & Error Correction Algorithms
ensure Accurate Data Transmission

Specifications:

Media: 2.4GHz Spread-Spectrum Radio
Range: up to 1500ft indoors with omnidirectional antenna

up to 12 miles line-of-sight with directional antenna

Protocol: MODBUS ASCII
Speed: 9600 BAUD
Radio Power Output: 1000mW max.
Operating Temperature: -4°F to +140°F (-20°C to +60°C)
Relay Contacts: 10A 1/8Hp @ 125VAC

6A 1/8Hp @ 277VAC

Power: 117 VAC, 60/50 Hz, 24VDC Available
Enclosure: NEMA4X (NEMA12 available as an option)

Model: RCI-200-RF2

Remote Control Signal Interface

With 2.4GHZ Radio Frequency Link

Page J10

Manufacturers of Process

Controls and Instrumentation

- R: Remote Radio

(Radio is in separate
enclosure and mounts
close to antenna to
prevent signal loss for
long cable runs)

Содержание Model: RCI-200-RF2

Страница 1: ...00 XXX If special or required 24 VDC 2 Dry Contacts and 2 Analog Inputs Input Remote Control Signal Interface XXX SER RS 232 485 Output 2 Form C Contacts and 2 Analog Outputs 117VAC 50 60Hz XXX RF9 90...

Страница 2: ...ducts or all non standard products may not be returned for restocking Pribusin Inc warrants equipment of its own manufacture to be free from defects in material and workmanship under normal conditions...

Страница 3: ...pread Spectrum Radio Technology Provides Reliable Communication 2 Dry Contact and 2 Analog Inputs 2 C Relay Contacts and 2 Analog Outputs Point to Point or Host to Multipoint Topologies No Calibration...

Страница 4: ...ct OR Master Remote 1 2 Analog 2 Contact 2 Analog 2 Contact Remote 2 Remote 3 Master to Multi Remote 2 Analog 2 Contact 2 Analog 2 Contact 2 Analog 2 Contact 2 Analog 2 Contact Page J10 any system 11...

Страница 5: ......

Страница 6: ......

Страница 7: ...a 500mA SLOBLO fuse It can be wired for 240VAC operation by removing de soldering power jumpers J1 J2 and installing soldering jumper J3 When changing the RCI 200 to 240VAC power make sure to change t...

Страница 8: ...inputs are connected to the RCI 200 in two fashions 1 Normal 3 wire connection or 2 two wire connection On a 3 wire connected input an external power supply or the 24V power output terminal of the RCI...

Страница 9: ...or from the inputs Care must be taken when connecting the outputs to different devices so that no inadvertent ground loops are established Output Calibration Input Testing The outputs on the RCI 200 a...

Страница 10: ...communications failure occurs If H1 3 IN then analog output 1 will ramp to the setting of K1 and analog output 2 will ramp to the setting of K2 Both outputs will change at a rate determined by the set...

Страница 11: ...In addition there are two types of Topologies that can be configured 1 Point to Point and 2 Host to Multipoint In a Point to Point topology one host communicates with one remote The two exchange all t...

Страница 12: ...the Standard mode of operation unless a repeater is required in your system Host Configuration To make an RCI 200 operate as a host unit make sure that SW2 8 is flipped down Next set the number of re...

Страница 13: ...al Strength Indicator RSSI Repeater Mode Only The Signal Strength indicator is active in the Repeater Mode only The radio communications board has a signal strength indicator to show the level of the...

Страница 14: ...n This means that there are no obstructions between the host antenna and each of the remote antennas This may require the antenna to be raised on a mast with some low loss coaxial cable being installe...

Отзывы: