Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a Authorized Service Center.
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.
WARNING
WARNING
Power Requirements
3
ESMA-4-1/2P4
21355
4
1
/
2
”
Class II
60 Hz
Mini angle grinder
18 AWG x 2C with insulating temperature of 221 °F
20 minutes work per 10 minutes idle.
Maximum 1 and a half hour hours per day.
4 A
0.6 Hp
Code
Description
Discs
Voltage
Frequency
Current
Power
Speed
Duty cycle
Conductors
Insulating
IP20
IP Grade:
Power cord grips used in this product: Type “Y”.
Build quality: Reinforced Insulation
Thermal insulation on motor winding: Class B
127 V
Technical Data
from 0 A and up to 10 A
from 10 A and up to 13 A
from 13 A and up to 15 A
from 15 A and up to 20 A
18 AWG(*)
16 AWG
14 AWG
8 AWG
16 AWG
14 AWG
12 AWG
6 AWG
3 (one grounded)
from 6 ft to 49 ft | higher than 49 ft
Ampere
Capacity
Number of
Conductors
Extension gauge
* It is safe to use only if the extensions have a built-in artifact for over current protection.
AWG = American Wire Gauge. Reference: NMX-J-195-ANCE-2006
Tools with double insulation and reinforced insulation are
equipped with a polarized plug (one prong is wider than the other). This plug will
only fit in the right way into a polarized outlet. If the plug cannot be introduced
into the outlet, reverse the plug. If it still doesn’t fit, call a qualified electrician to
install for you a polarized outlet. Do not alter the plug in any way. Both types of
insulation eliminates the need of both a grounded third power cord with three
prongs or a grounded power connection.
When using an extension cable, verify the gauge is enough for the power that your product needs. A lower
gauge cable will cause voltage drop in the line, resulting in power loss and overheating. The following table shows the right
size to use depending on cable’s length and the ampere capability shown in the tool’s nameplate. When in doubt use the
next higher gauge.
WARNING
WARNING
ENGLISH
WARNING
When operating power tools outdoors, use a grounded
extension cable labeled “For Outdoors Use”. These extensions are especially designed
for operating outdoors and reduce the risk of electric shock.
11 000 RPM
5/8-11-UNC-1A
Screwed thread size