background image

HLD-SLD PRESTO-ECOA OWNER’S MANUAL   9

IINSTALLATION INSTRUCTIONS

1. Check pit for conformity to installation drawing provided.

2. Locate the power unit. 

Note: It is suggested that power unit be installed prior to the installation of the lift. This 

allows the  electrical work to be completed ahead of time. Also, it permits flushing of the

hydraulic lines with the power unit prior to connecting the lift. 

Note: Hydraulic oil is not supplied with the equipment, unless the optional installation kit

has been purchased.

3. All underground hydraulic lines must be flushed with clean oil.

4. Remove the skid and all steel strapping. The unit comes with four (4)-lifting tabs fitted on the 

platform. These are to be used for lifting the unit with a crane or a fork truck.  At this point DO 

NOT remove the two (2) shipping bolts.

5. With the help of a crane or fork truck, lift the dock lift unit and position it in the pit. Note that the 

hydraulic cylinder end is opposite to the end of the oil line recess in the pit.

6. Remove the two (2) shipping bolts. Lift the dock lift with the help of a fork truck. Make sure that 

the base frame assembly remains on the ground and that the scissor legs open properly. Engage 

the maintenance devices as explained in “Scissor Blocking Instructions” section. Check to ensure 

that the maintenance safety bars are securely in place.

7. After flushing the hydraulic lines, proceed as follows:

Connect the hydraulic hose coming from the conduit to the Flare bulkhead  fitting on the base 

frame assembly.

Note: The hydraulic hose is not typically supplied by Presto-ECOA. Hose and tubng supplied by 

others must conform to manufacturer’s specifications.

8. The upper travel limit switch is factory installed to the bracket on the base frame at the scissor 

leg clevis hinge. Make sure the limit switch wire runs through the conduit to the control box.

Press the “UP” button until the cylinders are filled with oil and the lift rises.

9. Disengage the maintenance safety bars as explained in “Scissor Blocking Instructions” section. 
Completely lower the platform by pressing the ‘’DOWN’’ button until the unit is in fully lowered 
position. (Note: Motor runs only when the Lift is rising. Only the Solenoid operates when the Lift is 
lowering.)

10. Position the lift so that there are proper clearances around the edges (Refer to Installation 
drawing on page 9).

11. Raise the lift completely and engage the maintenance bars. Mark the base frame lag down 
holes; shift  the position of the lift to allow room for drilling, then drill. When complete, reposition 

the lift, shim until level. Install anchors, lagging the lift securely to the floor. (Make sure that base 

angles are fully supported along their entire length with shims or concrete grout.) Note: Anchoring 
holes may be drilled through existing holes using the base frame as a template.

Содержание SizzrDok HLD

Страница 1: ...nd Service Manual Model Number ___________________________ Serial ________________________________ Date placed in service _____________ IMPORTANT READ CAREFULLY BEFORE INSTALLING OR OPERATING LIFT Par...

Страница 2: ...as current at the time of printing To obtain the latest most updated version please contact Presto ECOA Lifts Customer Service Department or go to our website www PrestoLifts com where you will find a...

Страница 3: ...Pit Layout 12 OPERATING INSTRUCTIONS 16 ROUTINE MAINTENANCE 17 HYDRAULIC SECTION 18 ELECTRICAL SECTION 20 TROUBLESHOOTING 25 ORDERING REPLACEMENT PARTS 18 WARRANTY 26 List of Figures Figure 1 General...

Страница 4: ...many years of safe trouble free service If you have any questions about any of the instructions in this manual or about the use of this product PLEASE contact your DEALER or ECOA Inspection IMMEDIATEL...

Страница 5: ...ignal word NOTICE Safety instruction signs use signal words that are specific to the situation DANGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNIN...

Страница 6: ...capable of causing personal injury if proper precautions are not taken Therefore throughout this manual Presto ECOA Lifts have identified certain hazards which may occur in the use of the unit and pr...

Страница 7: ...E lifting personnel ALWAYS use a handrail to maintain balance while raising or lowering the lift SEVERE PERSONAL INJURY could result 6 NEVER leave the loaded dock lift unattended unless the lift platf...

Страница 8: ...Operators Only trained personnel and authorized personnel shall be permitted to operate these lifts Before Operation Before using the device the operator shall have Read and or had explained and unde...

Страница 9: ...safety bars are securely in place 7 After flushing the hydraulic lines proceed as follows Connect the hydraulic hose coming from the conduit to the Flare bulkhead fitting on the base frame assembly No...

Страница 10: ...rouble free operation of the lift 16 Check the oil level of the reservoir with the lift fully lowered It should be approximately 1 below the top of the tank Add oil if necessary 17 Clean up spilled oi...

Страница 11: ...the inside of the base end angle Ensure that the safety tabs on the maintenance bars are engaged over the side and base angles 6 Lower the dock lift by pressing the DOWN button until the rollers stop...

Страница 12: ...witch is purchased provide a 16 AWG 2 wire conductor type SO from the control box to the limit switch located within the lift base frame 5 Ensure the concrete is reinforced to suit local soil conditio...

Страница 13: ...HLD SLD PRESTO ECOA OWNER S MANUAL 13 FIG 2 General Layout...

Страница 14: ...14 HLD SLD PRESTO ECOA OWNER S MANUAL Fig 3 General Specifications...

Страница 15: ...HLD SLD PRESTO ECOA OWNER S MANUAL 15 Fig 4 Common Pit Layouts...

Страница 16: ...ts full vertical travel the cylinders have extended to its maximum limit The platform will no longer travel up due to the internal stops in the cylinders At this point the relief valve will open becau...

Страница 17: ...n clevis and pivot points for wear 4 Check for worn or damaged hydraulic hoses or electrical cords Repair as necessary 5 Check rollers for looseness and wear See Trouble Shooting 6 Check retaining rin...

Страница 18: ...lower the lift he or she presses the DOWN button This energizes the down solenoid valve The poppet in the solenoid valve is unseated and oil now returns from the cylinders through the flow control va...

Страница 19: ...HLD SLD PRESTO ECOA OWNER S MANUAL 19 FIG 5 Hydraulic Circuit Standard Scissor Model...

Страница 20: ...to National Electrical Code NEC 480 22 and applicable local codes NOTE If the available Power Supply is 208VAC 1PH 60Hz or 208VAC 3PH 60Hz it is typically necessary to supply booster transformers to...

Страница 21: ...HLD SLD PRESTO ECOA OWNER S MANUAL 21 FIG 7 Electrical Schematic Standard...

Страница 22: ...22 HLD SLD PRESTO ECOA OWNER S MANUAL FIG 8 Connection 460V 3PH FIG 9 Optional Connection 230V 1PH...

Страница 23: ...HLD SLD PRESTO ECOA OWNER S MANUAL 23...

Страница 24: ...24 HLD SLD PRESTO ECOA OWNER S MANUAL...

Страница 25: ...ts please call the Presto ECOA Parts Department Parts are shipped subject to the following terms FOB factory Returns only with the approval of our parts department Credit cards preferred except parts...

Страница 26: ...t cover labor expense for removal or reinstallation of components after thirty days This limited warranty shall not cover among other things damages result ing from foreign matter or water failure to...

Отзывы: