11
IMPORTANT
✓
The appliance should be installed, regulated and adapted to function with other types of
gas by a QUALIFIED INSTALLATION TECHNICIAN.
Failure to comply with this condition will render the guarantee invalid.
✓
The hob should only be installed by a C.O.R.G.I. registered installer.
✓
The appliance must be installed in compliance with regulations in force.
✓
Installation technicians must comply to current laws in force concerning ventilation and
the evacuation of exhaust gases.
✓
Always unplug the appliance before carrying out any maintenance operations or
repairs.
✓
The appliance must be housed in heat-resistant units.
✓
These tops are designed to be embedded into kitchen fixtures measuring 600
mm in depth.
✓
The walls of the units must not be higher than work top and must be capable of
resisting temperatures of 75 °C above room temperature.
✓
Do not install the appliance near inflammable materials (eg. curtains).
ADVICE
FOR THE
INSTALLER
room volume
air vent necessary (effective area)
6 m
3
to 9 m
3
65 cm
2
6 m
3
to 9 m
3
35 cm
2
Greater than 11 m
3
no air vent necessary
A room 6 m
3
to 11 m
3
with a door
no air vent necessary
opening to the outside
VENTILATION
All rooms require an openable window or equivalent, while some rooms require a perma-
nent vent in addition to a window that can be opened.
This unit must not be used in a room with less than 6 m
3
.
The above requirements allow also for use of a gas oven and grill but if there are other
gas burning appliances in the same room, consult a qualified engineer.