29
Fig. 10.3
J
INJECTORS REPLACEMENT OF HOB
BURNERS
The diameter is marked on the injector
in cents of millimetre.
Select the injectors to be replaced
according to the “Table for the choice of
the injectors” (page 30).
To replace the injectors:
• Remove the gratings, the burner and
the covers;
• Using a wrench, substitute the nozzle
injectors “J” (Fig. 10.3) with those
most suitable for the kind of gas for
which it is to be used.
CONVERSION TO LPG
ADJUSTING OF THE MINIMUM OF
THE HOB BURNERS
In the minimum position the flame must
have a length of about 4 mm and must
remain lit even with a quick turn from the
maximum position to that of minimum.
The flame adjustment is done in the fol-
lowing way:
• Turn on the burner
• Turn the tap to the MINIMUM position
• Take off the knob
• With a small flat screwdriver turn the
screw inside the tap rod to the correct
regulation (fig. 10.4).
Normally for LPG, tighten up the regula-
tion screw.
Fig. 10.4
The burners are conceived in such a
way so as not to require the regula-
tion of the primary air.
Содержание PR1-D60