KEY IN SENSOR CIRCUITS:

If the vehicle you are working on does not have or you cannot locate the ECM reference wire, there are
two alternatives available.  Although not preferred, the vehicle Key In Sensor may be reconfigured to allow
a margin of safety and will prevent the vehicle with a Mechanical Neutral Start Switch from starting in gear.
AUDIOVOX ADVISES THAT YOU MAINTAIN THE FACTORY CIRCUIT WHENEVER POSSIBLE.  The
following two circuits may be used only if the above circuit is not available.

NOTE:

  When completing an installation using either of the following key in sensor circuits, if the operator

inserts the ignition key while the vehicle is running under the control of the Remote Start, the
vehicle will shut down.  This must be explained to the operator as it is in contrast to the normal
operation of a vehicle utilizing an electrical neutral start switch and is inconsistent with the opera-
tors manual.

Additional information concerning Key In Sensor methods 1 & 2 are listed below and should be reviewed
before considering either alternative.
Method 1 will allow the safety required for  the remote start unit and prevent the vehicle from starting while
in any gear other than Park or Neutral while the key is in the ignition cylinder however, if the key is left in
the ignition switch and the door is left opened, the added relay will be energized causing a 150mA drain on
the battery.
Method 2 will allow the safety required for the remote start unit and prevent the vehicle from starting while
in any gear other than Park or Neutral while the key is in the ignition cylinder however, the original factory
key in chime module will not alert the owner that the key has been left in the ignition switch.  In addition,
this may also effect other warning tones such as the light on reminder.
These situations should be carefully considered before altering the vehicle's wiring and must be fully
explained to the consumer.

METHOD 1

To connect to the key in sensor as shown in method 1:
A. Locate the control wire that connects the drivers door pin switch to the key in sensor switch.
B. Cut this wire and connect the ignition cylinder side to chassis ground.
C. Locate the key in sensor switch wire that connects the chime module to the ignition cylinder .
D. Cut this wire and connect the ignition cylinder side to terminal 30 of a P&B VF45F11 or equivalent relay.
E. Connect the cathode (striped) side of a 4002 series diode to this same wire, and connect the (non

striped) side to the negative shut down safety wire (Gray / Black) of the Audiovox Remote Start Unit.

F.  Connect terminal 86 of the relay to a fused +12 volt constant battery source.
G. Connect terminal 87 of the relay to the Chime Module side of the previously cut wire in step D.
H. Connect terminal 85 of the relay to the Drivers Door side of the pin switch wire previously cut in step B.

NOTE:

  A second 4002 series diode may be required to maintain the integrity of the hood open, shut down

circuit.  If this is the case, it must be installed as shown in the diagram above.  The anode (Non
Striped) side must be connected to the Gray/Black wire of the Remote Start Unit.  The cathode
(Striped) side must be connected to the hood pin switch.  If the hood pin switch is also used for an
alarm trigger input, be certain to use the dual diode assembly packaged with the Audiovox Re-
mote Start Unit as shown below.

18

Содержание 1286568

Страница 1: ...issions Only Kit Contents Control Module 2 4 Button Code Hopping Transmitters 4ChannelCodeLearningReceiver ExternalSuperheterodyneAntenna Receiver 1 Multi Pin Input Output Harness 1 Six Pin Power Harn...

Страница 2: ...hosen location to insure the drill will not penetrate any existing factory wiring or fluid lines Drill a 1 4 hole in the desired location and thread the pin switch into it using a 7 16 nut driver or d...

Страница 3: ...eparate feed wires must be used for the Red and Red White wires If your vehicle does not have two battery feed wires at the ignition switch then it is possible to connect both wires to the vehicle s b...

Страница 4: ...y is turned to the OFF and ACCESSORY positions For Diesel Applications this wire must be connected to the ignition circuit that powers the glow plugs if the vehicle requires glow plug pre heating See...

Страница 5: ...ch provided This wire will be routed through the fire wall into the engine compartment It is necessary to use an existing grommet when passing wires through the fire wall to prevent short circuiting T...

Страница 6: ...output when the ignition key is turned to the ON position and 0 Volts when the ignition key is OFF and when the vehicle is running under the control of the remote starter This wire should be connected...

Страница 7: ...wire to terminal 30 and the other end of the cut wire to terminal 87a Just before the Remote Start unit is activated the relay contacts will open preventing the shock sensor s operation until the Remo...

Страница 8: ...hite Connector The Red Green Door Lock Unlock output wires provide either a pulsed ground or pulsed 12 volts to control the vehicle door lock unlock circuits The Red Black 2nd Unlock output wire provi...

Страница 9: ...terminal 87a of the optional relay added Connect the green wire of the 3 pin harness to terminal 86 of the optional relay added Connect terminal 85 of the optional relay added to a fused constant 12...

Страница 10: ...3 pin harness to terminal 86 of the optional relay added Connect terminal 85 of the optional relay added to chassis ground Most vehicles door lock unlock motor legs rest at ground and switch 12 volts...

Страница 11: ...SS The auxiliary 4 pin connector provides low current outputs to control various functions in the vehicle during different stages of the Remote Start unit s operation Understanding these outputs and t...

Страница 12: ...NING Connectingthedarkbluewiretothehighcurrentswitchedoutputofthetrunkreleasecircuitsand some remote start trigger inputs will damage the control module Connect the dark blue wire to terminal 86 of th...

Страница 13: ...e black w white trace wire to terminal 86 of the AS 9256 relay or an equivalent 30 Amp automotive relay and connect relay terminal 85 to a fused 12 VDC battery source Connect relay terminal 87 to the...

Страница 14: ...thout first programming tach the unit will flash the parking lights 7 times indicating tach has not been learned and stored If the tach rate is not properly programmed to the specific vehicle the unit...

Страница 15: ...vehicles where single point ignition coil or single injector cannot be learned or single point tach signal is unavailable To use the adaptor the Green Black wires must connect to the negative side of...

Страница 16: ...selector is in any position other than Park or Neutral When installing a Remote Start Device it is imperative that the Yellow Starter wire be connected to the ignition switch side of the Neutral Star...

Страница 17: ...the key is left in the ignition switch regardless of the gear selectors position PARK NEUTRAL ECM INPUT The Park Neutral ECM input is the preferred method of installation This not only maintains the i...

Страница 18: ...the ignition cylinder however the original factory key in chime module will not alert the owner that the key has been left in the ignition switch In addition this may also effect other warning tones s...

Страница 19: ...in this manual COMPLETING THE INSTALLATION After you have confirmed the operation of the Audiovox Remote Start unit and tested all the safety features of the system 1 If you have not done so already p...

Страница 20: ...128 6568 20 of 20 2003 Audiovox Electronics Corp Hauppauge N Y 11788 128 6568...

Отзывы: