Operating instructions two-hand grease gun
8.1. Advises for an ideal operation
NOTE
Since the piston chamber of the grease gun is not filled by spring pressure, but
by the vacuum created by the piston, never open the hand lever jerkily.
■
■
Operate the grease gun with even and steady working strokes.
■
■
Depending on the viscosity of the grease used (based on the NLGI class and
the temperature), the vacuum technology makes it necessary to wait for a
sufficient refilling of the piston chamber with grease.
9. Care/Maintenance
The two-hand grease gun needs little care and maintenance.
Because of operator responsibility, the following parts must be checked regularly in order to avoid
environmental, material or personal damage:
– Grease gun head
– Screwed connections
– Accessories (hoses, mouthpieces, etc.)
10. Accessories according to DIN 1283
(Extract from the Pressol range of accessories)
Item Description
M 10 x 1
G 1/8“
1
Precision mouthpiece
12 643
12 743
2
Angled spout
12 635
12 735
3
Straight spout
12 435
12 475
4
High pressure hose, 11 x 300 mm
12 655
12 735
5
High pressure hose, 11 x 500 mm
12 665
12 765
6
Adapter, G 1/8“ f, M 10 x 1 m
12 016
11. Repairs/Service
The grease gun was developed and manufactured under compliance with the highest quality standards.
If in spite of all quality measures a problem occurs, please get in touch with our service contact partners:
Pressol Schmiergeräte GmbH
Tel +49 9462 17-246
Fax +49 9462 1063
[email protected]
12. Disposal
The operating company is responsible for the proper disposal of the two-hand grease gun.
Dispose of the different materials in accordance with all industry-specific, local, regional and federal
regulations.
Only qualified personnel is authorized to disassemble and dispose of the grease gun.