58
Error
Display
Fault Alarm Description
Problem
F11
CAN-bus halt
X
CAN-bus halt detected.
One of the devices on the bus has
a fatal CAN error or has rebooted.
F12
F13
F14
F15
F16
F17
F18
F19
F20
RTC comm.
X
Communication with RTC not
correct
Call a service technician
F21
F22
Main power error
X
Display was rebooted
Check power supply
F23
Software vers.
X
Software version does not
correspond
Check the software versions of the
PressControl [JGA953] and
ColorPressDisplay [JGA1085]
F24
PressControl N/A
X
No connection with PressControl
Check the CAN-bus connection to
the PressControl [JGA953]
F25
F26
F27
F28
Uart rxFifo
X
UART receive buffer full
Too much debug information send,
or noise on the connection.
F29
Uart txFifo
X
UART send buffer full
F30
F31
F32
F33
F34
F35
F36
F37
F38
F39
F40
F41
F42
F43
Uart rx data
X
Communication error
Call a service technician
F44
Uart rxFifo
X
F45
Uart frame length
X
F46
Uart frame BCC
X
F47
F48
F49
F50
IP-conflict
X
There is a device in the computer
network wit the same IP-address
Check network settings
F51
MAC-address
X
MAC address error
Call a service technician
F52
W5500 cmd
X
Factory error message
F53
NTP connection
X
Connection to the timeserver
could not be established.
Check access to the internet / time
server
F54
F55
Timer handler
X
Factory error message
Call a service technician
F56
Содержание HORNIT N2