High Mid Band Gain:
Sets the attenuation or boost of the EQ’s high-mid band. The
gain can be set between -16 and +16 dB.
High Band Frequency:
Sets the center frequency of the EQ’s high-frequency band.
You can adjust the center frequency from 2 kHz to 20 kHz.
High Band Gain:
Sets the attenuation or boost of the EQ’s high band. The gain can be
set between -16 and +16 dB.
High Band Peak:
When the Peak switch is engaged, the high band of the EQ
becomes a standard peak filter with a fixed Q of 0.6. When it is disengaged, the high
band is a shelving filter.
2.4
VU Meter and Controls
VU Meter:
The analog VU meter displays the ADL 700’s
output level. When the Meter – GR switch is enabled, the
VU meter will show the amount of gain reduction being
applied by the compressor.
Meter -6 dB:
This switch offsets the VU meter by 6 dB, which can help you meter loud
input sources if your VU meter is “slamming” or pegged.
VU Meter and Controls 2.4