11
1.
Turn the rotary
CH
knob (
3
) or use the
UP
/
DN
keys (
14
) on the microphone
to
select
the
SWR
function.
2.
Press the
F
key (
9
). The radio automatically goes to
TX
mode without press-
ing
PTT
switch (
13
) . The
SWR
measurement starts. Measurement time is 5
minutes maximum. The remaining time is displayed.
3.
Adjust your antenna.
4.
The beep tone
*
is continuous when SWR value is equal to
1.0
. The space
between two beeps becomes longer when SWR value moves away from
1.0
.
Volume of the beep tone is adjustable with
VOLUME
knob (
1
).
Display shows the
SWR
value. For example
2.5
.
5.
Press the
PTT
switch (
13
) to
exit
MENU
mode. disappears from the display.
*
Please check that the beep volume is set to a comfortable listening level.
See §
HOW TO ADJUST SWR
page 6.
6) EMG SET 1
Allows to
set
the channel for Emergency Channel 1.
Press the
F
key (
9
) to
enter
MENU
. is displayed.
1.
Turn the rotary
CH
knob (
3
) or use
UP
/
DN
keys (
14
) on the microphone to
select
the
EMG 1
function.
2.
Press the
F
key (
9
) to
validate.
The current channel blinks on LCD.
3.
Turn the rotary
CH
knob (
3
) or use
UP
/
DN
keys (
14
) on the microphone to
select
the emergency channel.
4.
New press on the
F
key (
9
) to
validate
. The channel stops blinking.
a
) Go to
point
1
to
adjust
another function or
b
) Press the
PTT
switch (
13
) to
validate
and
exit
MENU
. disappears.
5.
If no key is pressed, the unit
exits
MENU
after 10 seconds, disappears from
the display.
Default emergency channel 1 is
9
.
See §
EMERGENCY CHANNELS
page 8.
7) EMG SET 2
Allows to
set
the channel for Emergency Channel 2.
Press the
F
key (
9
) to
enter
MENU
. is displayed.
1.
Turn the rotary
CH
knob (
3
) or use
UP
/
DN
keys (
14
) on the microphone to
select
the
EMG 2
function.
Points
2
to
5
are identical to §
EMG SET 1
.
Default Emergency channel 2 is
19
.
See §
EMERGENCY CHANNELS
page 8.
8) VOX SETTING
Press the
F
key (
9
) to
enter
MENU
. is displayed.
1.
Turn the rotary
CH
knob (
3
) or use
UP
/
DN
keys (
14
) on the microphone to
select
the
VOX
function.
Three adjustments are possible: Sensitivity
L
/ Anti-vox level
A
/ Vox delay time
t
(over and over).
2.
Press the
F
key (
9
). The current
setting
(
L
,
A
or
t
) blinks on the LCD.
3.
Turn the rotary
CH
knob (
3
) or press the
UP/DN
(
14
) keys on the microphone
to
move
to next setting or...
4.
Press the
F
key (
9
). The
value
of the current setting blinks on the LCD.
5.
Turn the rotary
CH
knob (
3
) or press the
UP/DN
(
14
) keys on the microphone
to
adjust
the
value
of the setting.
6.
Press the
F
key (
9
) to
store
and
validate
the setting.
7.
Go to point
2
to set both others adjustments of
VOX
.
8.
Once the settings done, press the
PTT
switch (
13
) to
exit
the
VOX Adjustment
mode. If no adjustment is made for 10 seconds, the unit automatically
exits
the function.
-
Sensitivity
L
: allows the adjustment of the microphone (original one or
optional vox) for an optimum transmission quality. Adjustable level from
1
(high level) to
9
(low level).Default value:
5
.
-
Anti-Vox
A
: allows disabling the transmission generated by the surrounding
noise. The level is adjustable.
OF
(according the squelch level) and from
0
(without anti-vox) to
9
(low level). Default value:
OF
.
-
Delay
time
t
: allows avoiding the sudden cut of the transmission by adding
a delay at the end of speaking. The level is adjustable from 1 (short delay)
to 9 (long delay). Default value;
1
.
VOX SETTING
don’t automatically activate the
VOX
function.
9) PA SETTING
This function allows to
select
the operating mode of Public Address.
Press the
F
key (
9
) to
enter
MENU
. is displayed.
1.
Turn the rotary
CH
knob (
3
) or use
UP
/
DN
keys (
14
) on the microphone to
select
the
PASET
function.
2.
Press the
F
key (
9
) to
validate.
The current value blinks on LCD.
3.
Turn the rotary
CH
knob (
3
) or use
UP
/
DN
keys (
14
) on the microphone to
select
the operating mode of the PA :
In
,
OF
or
PA
.
4.
New press on the
F
key (
9
) to
validate
. The parameter stops blinking.
a
)
Go to point
1
to
adjust
another function or
b
) Press the
PTT
switch (
13
) to
validate
and
exit
MENU
. disappears.
5.
If no key is pressed, the unit
exits
MENU
after 10 seconds, disappears from
the display.
In
: the
modulation of the microphone
is transmitted to external loudspeaker
connected to jack PA.SP. (
D
). The
received signal
is transmitted to the
English
Содержание Taylor FCC
Страница 1: ...Owner s manual Manual del usuario Manuel d utilisation Manual do usuário 12 24 V ...
Страница 58: ...58 ...
Страница 59: ...59 ...