PRESERVATECH MINI ONE XL Скачать руководство пользователя страница 9

 

 

MINI ONE XL - MANUAL

 

 

 

9

 

www.preservatech.com

 

 

VENTILATION 

If the unit is enclosed, be sure that there is adequate air available for cooling. For the most effective 
operation, do not allow ambient temperatures around the unit to rise above 75 F / 24 C. Warm 
temperatures may reduce the ability of the unit to provide lower humidity’s. 
Should the unit be mounted in an enclosure (e.g. beneath the showcase),  
provide at least TWO ventilation holes. A flexible exhaust hose must be attached to the 
four inch / ten centimetre mounting on the front of the unit, and directed out of the 
enclosure through one of the ventilation holes.  
Adequate fresh air for cooling must be provided, through a hole(s) 
totalling at least 16 square inches / 100 sq. cm. All ventilation holes’ must  
be unimpeded (do not cover with any cloth, mesh, or perforated metal).  
Avoid re-circulating exhaust air by separating the holes as far from each other as  
possible. For example, provide an upper hole for connection to the exhaust hose and a 
lower hole for fresh air intake. Be aware of walls or obstructions which might trap and 
re-circulate exhaust air into the fresh air intake. 
 

NOTE: Although all Mini One XL machines are ready to connect a 4" (100 mm) exhaust hose and hose 
termination, they are not included in the standard shipment and must be ordered separately.  

WiFi ANTENNA 

WiFi Antenna needs to be installed only if 
monitoring service is in use. If the machine is 
located inside a metal enclosure (eg. Under a 
case made of steel) it is highly possible that the 

WiFi connection will be poor or non-existent. In this situation, the antenna 
needs to be installed outside of the metal enclosure. Wifi antenna extension 
cord can be supplied by Preservatech. (Antenna is included in a standard order; 
extension cord is an additional option)  

EXTERNAL CONNECTION 

The Mini One XL is equipped with external connectors: 
 
RH - The "OUT OF RANGE" alarm is a 12 VDC connector to power up an LED or other 12VDC device. 
This alarm is activated when the RH at the sensor is lower or higher then SET VALUE ± “Rh error 
offset” parameter (see Programming)  
 
LW - The “LOW WATER" alarm is a 12 VDC connector to power up an LED or 
other 12VDC device. This alarm is activated when the water level inside machine 
falls below the lowest acceptable level. Water must be added to the machine 
when this alarm is activated. 
 
ER - The "EXTERNAL RESERVOIR" jack is used for connecting a automatic filling system or with water 
reservoir. 

 

NOTE: Although all Mini One XL machines are equipped with external 
connectors, cables and LED's are not included in the standard shipment. They 
must be ordered separately. 

 
 

Содержание MINI ONE XL

Страница 1: ...MINI ONE XL MANUAL 1 www preservatech com MINI ONE XL ORIGINAL INSTRUCTIONS Year 2019 Manufacturer Preservatech Europe sp z o o Równa 1 85 846 Bydgoszcz Poland info preservatech eu ...

Страница 2: ...AIN 6 WATER RESERVOIR 6 AIR PUMPS 7 CONNECTION OF AIR HOSES TO THE CASE 7 SENSOR CONNECTION 8 VENTILATION 9 WiFi ANTENNA 9 EXTERNAL CONNECTION 9 OVERFLOW PORT 10 OPERATION MANUAL 10 AUTOMATIC FILLING SYSTEM 10 WATER RESERVOIR 10 STARTING MACHINE 10 TOUCH SCREEN DISPLAY 11 PROGRAMMING 12 NETWORK CONFIGURATION 14 USING DATA LOGGER 15 SHIPPING AND STORAGE 15 LIMITED MICROCLIMATE GENERATOR WARRANTY 16...

Страница 3: ...I ONE XL MANUAL 3 www preservatech com INSTALLATION Please carefully read all the information in this manual to ensure proper operation of the Mini One humidity generator MAIN UNIT AIR PUMP WATER RESERVOIR ...

Страница 4: ...onnector Quantity as per order RH T sensor 1 pc with up to 125 meters cable As per order Water reservoir or automatic filling set Automatic filling set includes RO system Power cord 1 pc WiFi Antenna Optional parts need to be ordered as additional parts Alarm cables with LED Additional Air connectors for multiple case installation Additional hose Additional air pump s SD Card for data logger Exten...

Страница 5: ...the cases INSTALLATION GUIDE An improper installation can severely compromise the operation of the unit A level operating surface adequate ventilation and good access are imperative OPTIONS FOR INSTALLATION Depends on the chosen version system can be installed with Automatic filling system needs access to a tap water source or External water reservoir which holds up to 20 liters of water Machine c...

Страница 6: ...ic filling is in use for safety reasons we strongly recommend connecting Overflow fitting on the machine front with a drain Drain should be located near the machine and should be a minimum of 100 mm below Overflow fitting Valve electrical cable must be connected to the jack labelled EP on the front panel of the machine WATER RESERVOIR If automatic filling is not possible machine needs to be connec...

Страница 7: ...vice which is connected to the case s by a single or multiple hoses Depending on the size and distance of the cases Ø6 Ø8 Ø10 and Ø14 mm hoses may be used with a maximum length up to 100 meters Machine as a standard has a two outputs Ø 14 mm but depending on the users needs a adapter can be used with up to 9 outputs with varying Ø Also as an option rotameters can be added Preservatech also supplie...

Страница 8: ...ONNECTION Digital RHT sensor supplied with Mini One XL is built inside brass housing Ø 9 32 Cable can be up to 120 meters long Preservatech supplies a standard 10 meter long sensor unless otherwise specified by client If for any reason client wants to use their own cable it must be a shielded 4 twisted pairs CAT 5 communication cable If possible the sensor should be located in the case closest to ...

Страница 9: ...m exhaust hose and hose termination they are not included in the standard shipment and must be ordered separately WiFi ANTENNA WiFi Antenna needs to be installed only if monitoring service is in use If the machine is located inside a metal enclosure eg Under a case made of steel it is highly possible that the WiFi connection will be poor or non existent In this situation the antenna needs to be in...

Страница 10: ...chine will draw water automatically after starting Please note that a empty machine can takes up to 2 hours to start Please refer to Water and drain chapter for more information WATER RESERVOIR Before filling the water reservoir it must be connected to a power outlet and the machine must be turned ON When filling the machine keep an eye on the water level indicator on the controller until it displ...

Страница 11: ...t BLINKING OUT OF RANGE STATUS IS DETERMINED BY PARAMETER RH error offset see Programming Chapter C Target RH Can be adjusted by arrows on the right K and L D Temperature measured by the machine s sensor inside the display case E Water level inside the machine Under normal condition black letters If water level drops below minimum letters become RED and start BLINKING F Status of the air pump G Di...

Страница 12: ... treatment box Read only Used by controller Air pump control Default value 1 Periodically the machine will turn off the air pump which is part of normal operations This setting must be set to 1 in order for the pump to shut off in case of a malfunction If this parameter is changed to 0 the air pump will be always ON Under normal circumstances it should always be set to 1 Temper error level Paramet...

Страница 13: ... chapter Master Slave Configuration for more detailed information TR Slave Mode For setting a machine as a Slave See chapter Master Slave Configuration for more datailed explanation TR Slave address If a machine is set as a master this parameter must correpond with the slave machine s Must be different then master machine communication address See chapter Master Slave Configuration for a more in d...

Страница 14: ...tton located on the right 3 After entering this mode display shows among others Hub id WiFi SSID network name and WiFi Pass For proper operation SSID and Pass must be set to access local WiFi network 4 Using your smartphone choose connection with Hubxxxxx Machine must be in Wifi config mode 5 Within a few seconds after login a new page with the machine data will pop up 6 Enter proper SSID Name of ...

Страница 15: ...ystems are not compatible with data loggers For the proper operation of the data logger Date and Time as well as time interval must be set accordingly Please see Programming chapter for instructions how to set Time and Date SHIPPING AND STORAGE The Mini One XL should be stored in a clean area with temperature between 5 C 30 C and relative humidity below 80 All cables hoses and attachments must be ...

Страница 16: ...other warranties conditions representations or guarantees including any warranties conditions representations or guarantees under any Sale of Goods Act or like legislation or statue is hereby expressly excluded Save as herein provided Preservatech shall not be responsible for any damages to persons or property including the unit itself howsoever caused or any consequential damages arising from the...

Страница 17: ...ide a museum display cases Manufacturer Preservatech Europe sp z o o Rowna 1 85 846 Bydgoszcz Country of origin Poland The above mentioned product complies with following regulation EU Low Voltage Directive 2006 95 EC EU Electromagnetic Compatibility Directive 2004 108 EC Harmonised Standards EN 60335 2 98 2003 A2 2008 EN 61000 6 3 2007 A1 2011 EN 61000 6 1 2007 Signed DEC 11 2018 in Bydgoszcz Jan...

Отзывы: