MINI ONE XL - MANUAL
11
www.preservatech.com
TOUCH SCREEN DISPLAY
Touch screen is divided into a few areas
with different purposes. Below is an
explanation of all the display areas.
Display will turn off after 10 minutes of
being idle. Lightly tap the display to turn
it back on.
A
Humidity generator model (M)
B
Relative humidity measured by machine’s sensor (inside the display case)
Under normal conditions, the digits are blue, when measured RH is out of range, digits become
RED and start BLINKING.
OUT OF RANGE STATUS IS DETERMINED BY PARAMETER “RH error offset” (see “Programming
Chapter”)
C
Target RH. Can be adjusted by arrows on the right (K and L)
D
Temperature measured by the machine’s sensor (inside the display case)
E
Water level inside the machine. Under normal condition, black letters. If water level drops
below minimum, letters become RED and start BLINKING.
F
Status of the air pump.
G
Displays the minimum and maximum values for RH and T in last 24 hours.
H
Button for programming mode. See chapter: Programming.
K & L
Arrows to change target RH value. Use K to raise target RH, L to lower target RH.
M
Shows status of WiFi connection.
i = Wi-Fi initialized
C = Connected to server