PREPLINE PSP40 Скачать руководство пользователя страница 9

 

                                                                              PSP40 

            . 

.

 

8.

8.

8.

8.

 

     Troubleshooting

Troubleshooting

Troubleshooting

Troubleshooting    

8888.1 

.1 

.1 

.1 Troubleshooting

Troubleshooting

Troubleshooting

Troubleshooting    

SYMPTOM

SYMPTOM

SYMPTOM

SYMPTOM    

PROBABLE    CAUSE

PROBABLE    CAUSE

PROBABLE    CAUSE

PROBABLE    CAUSE    

REMEDY

REMEDY

REMEDY

REMEDY    

Will not power on 

Power cord not plugged in or properly 
connected. Power outlet not supplying electricity.   
Battery is low. Other failure. 

Check power cord connections. Make sure 
power cord is plugged into the power outlet. 
Check power source. Replace batteries. Or 
service required. 

Unable to zero the 
display or will not 
zero when turned on 

Load on scale exceeds allowable limits. 
Load on scale is not stable. 
Load cell damage. 

Remove load on scale.   
Wait for load to become stable.   
Service required. 

Lo.bAt is shown 

Battery is low 

Replace new batteries 

 
 
 

Содержание PSP40

Страница 1: ...PSP40 PSP40 PSP40 PSP40 User Technical Manual Contents subject to change without notice Version 1 0 04 2021 ...

Страница 2: ...ctions 4 4 4 4 4 OPERATIONS OPERATIONS OPERATIONS OPERATIONS 5 4 1 Power on Power off scale 4 1 Power on Power off scale 4 1 Power on Power off scale 4 1 Power on Power off scale 5 4 2 Zeroing the display 4 2 Zeroing the display 4 2 Zeroing the display 4 2 Zeroing the display 5 4 3 Normal 4 3 Normal 4 3 Normal 4 3 Normal Weighing Mode Weighing Mode Weighing Mode Weighing Mode 5 4 4 Taring 4 4 Tari...

Страница 3: ... Max Capacity Max Capacity Max Capacity 3 kg 6 lb 6 kg 12 lb 15 kg 30 lb 20 kg 40 lb Readability Readability Readability Readability 0 5 g 0 001 lb 1 g 0 002 lb 2 g 0 005 lb 10 g 0 02 lb Display Resolution Display Resolution Display Resolution Display Resolution 1 6000 1 6000 1 7500 1 2000 Min Recommended Weight Min Recommended Weight Min Recommended Weight Min Recommended Weight 10 g 0 1 lb 20 g ...

Страница 4: ...sure that the scale is level each time its location is changed Connect the supplied AC adapter to the power input receptacle underneath the scale Plug the AC adapter into a properly grounded power outlet If the scale will be stored or transported in the future save the packaging material to ensure the best possible protection for the scale Contents Contents Contents Contents Scale 9Vdc 600mA adapt...

Страница 5: ...PSP40 3 3 2 3 2 3 2 3 2 Indicator Display Indicator Display Indicator Display Indicator Display Character Definitions Character Definitions Character Definitions Character Definitions ...

Страница 6: ...s Key Functions Key Functions Button Functions Functions Functions Functions Short Press when off when on Long Press when on Power on the scale Sets display to zero Power off the scale Short Press Long Press Tare a weight Switch between unit of measure ...

Страница 7: ...3 3 Normal Weighing Mode Normal Weighing Mode Normal Weighing Mode Normal Weighing Mode When scale is powered on and back to 0 place the weighing objects on the platform The display will show the weight and the units of weight currently in use 4 4 4 4 4 4 4 4 Taring Taring Taring Taring Zero the scale by pressing the ON OFF ON OFF ON OFF ON OFF ZERO ZERO ZERO ZERO key if necessary when reading is ...

Страница 8: ...is on press and hold TARE TARE TARE TARE UNIT UNIT UNIT UNIT and ON OFF ON OFF ON OFF ON OFF ZERO ZERO ZERO ZERO buttons till SETUP is displayed then the xx is displayed xx 0 1 9 means when the scale has no weight changing and no key pressed for 1 9 minutes the scale will auto power off to save battery power when x 0 means no auto power off function Now press TARE TARE TARE TARE UNIT UNIT UNIT UNI...

Страница 9: ... not plugged in or properly connected Power outlet not supplying electricity Battery is low Other failure Check power cord connections Make sure power cord is plugged into the power outlet Check power source Replace batteries Or service required Unable to zero the display or will not zero when turned on Load on scale exceeds allowable limits Load on scale is not stable Load cell damage Remove load...

Отзывы: