Section 3 - INSTALLATION
15
© Copyright 2006 PREO SRL
All rights reserved
EAW530E2MV
Edition
03/2006
1
st
byte
[0]
header (always obligatorily zero)
2
nd
byte
[TANK]
new tank set-point
3
rd
byte
[HOSE1]
new hose 1 set-point
4
th
byte
[GUN1]
new gun 1 set-point
5
th
byte
[HOSE2]
new hose 2 set-point
6
th
byte
[GUN2]
new gun 2 set-point
7
th
byte
[PUMP]
new pump set-point
8
th
byte
[CHKSUM]
check-sum bytes transmitted
The applicator responds with a further 8 bytes, arranged as follows:
1
st
byte
[0]
header (always zero)
2
nd
byte
[tank]
current tank temperature
3
rd
byte
[hose1]
current hose 1 temperature
4
th
byte
[gun1]
current gun 1 temperature
5
th
byte
[hose2]
current hose 2 temperature
6
th
byte
[gun2]
current gun 2 temperature
7
th
byte
[pressure]
current glue delivery pressure
8
th
byte
[chksum]
check-sum bytes received
Note that the set-points and current temperatures are expressed in °C and must be
within the field of +2°C to +230°C.
Setting one of the set-points to one (1) causes the corresponding channel to be
switched off. For example, by transmitting 1 as the 3
rd
byte, the PC switches off
hose 1 completely. This is useful when you want to obtain machine consensus,
despite hose 1 being disconnected.
The parameters must NOT be set at zero, so as not to confuse them with the
header.
The check-sum (both in TX and RX) is calculated as follows: (2
nd
byte + 3
rd
byte +
4
th
byte + 5
th
byte + 6
th
byte + 7
th
byte) MOD 256. If the result amounts to zero
(header!), it is transformed to one.
Содержание EASY 5 Series
Страница 2: ......
Страница 8: ...Copyright 2006 PREO SRL All rights reserved EAW530E2MV Edition 03 2006...
Страница 24: ...16 Section 3 INSTALLATION Copyright 2006 PREO SRL All rights reserved EAW530E2MV Edition 03 2006...
Страница 32: ...24 Section 4 OPERATION Copyright 2006 PREO SRL All rights reserved EAW530E2MV Edition 03 2006...
Страница 40: ...32 Section 6 TROUBLESHOOTING Copyright 2006 PREO SRL All rights reserved EAW530E2MV Edition 03 2006...
Страница 55: ......