Buttons and functions
1. Adjust
: Decrease the set temp. Keeping pressing will decrease the temp with 1
℃
per 0.5s.
2. Adjust
: Increase the set temp. Keeping pressing will increase the temp with 1
℃
per 0.5s.
3. MODE
: Once pressing, running mode will be selected in the following sequence:
AUTO COOL DRY
HEAT FAN
NOTE: No heating mode for cool only type unit.
4. DIRECTION/VERT SWING:
Used to stop or start horizontal louver movement or set the desired up/down
air flow direction. The louver changes 6 degree in angle for each press. If keep pushing more than 2 seconds,
the louver will swing up and down automatically.
5. HORIZ SWING:
Used to stop or start vertical louver movement.
6. RESET
(inner located): Press this button with a needle of 1mm to cancel the current setting and reset
remote controller.
7. ON/OFF
: For turning on or turning off the air conditioner.
8. FAN SPEED:
Fan speed will be selected in following sequence once pressing this button:
AUTO LOW MED HIGH
9. TIME ON:
For time ON setting. Once pressing this button, the time will increase by 0.5 hour. When the set
time exceeds 10 hours, pressing the button will increase the time by 1 hour. Adjusting the figure to 0.00 will
cancel time ON setting.
10. ECO:
Activate or turn off economic operation mode. It is suggested to turn on this function when sleeping.
(Only available when remote controller is used with corresponding unit.)
11. TIME OFF:
For time OFF setting. Once pressing this button, the time will increase by 0.5 hour. When the
set time exceeds 10 hours, pressing the button will increase the time by 1 hour.
Adjust the figure to 0.00 will cancel time ON setting.
12. CLOCK:
Display the current time. (12:00 is displayed when resetting or electrifying for the first time.)
Press CLOCK for 5s, icon indicating hour will flash with 0.5s. Press it again; icon indicating minute will flash
with 0.5s.
and are used to adjust the figure. Setting or modification is effective only by pressing OK
button to make confirmation.
Содержание PAC247C-I
Страница 5: ......
Страница 9: ......
Страница 14: ...Service Space MLCAC UTSM 2011 02 12 Four way Cassette 3 Service Space 1000mm 1000mm 1000mm 1000mm ...
Страница 15: ...MLCAC UTSM 2011 02 Wiring Diagrams Four way Cassette 13 4 Wiring Diagrams PAC247C I PAC367C I ...
Страница 16: ...Wiring Diagrams MLCAC UTSM 2011 02 14 Four way Cassette PAC487C I ...
Страница 21: ...MLCAC UTSM 2011 02 Field Wiring Four way Cassette 19 8 Field Wiring Wiring chart PAC247C I PAC367C I ...
Страница 25: ...MLCAC UTSM 2011 02 Service Space Ceiling Floor Type 23 3 Service Space ...
Страница 26: ...Wiring Diagrams MLCAC UTSM 2011 02 24 Ceiling Floor Type 4 Wiring Diagrams PAC366FC I ...
Страница 27: ...MLCAC UTSM 2011 02 Wiring Diagrams Ceiling Floor Type 25 PAC486FC I PAC606FC I ...
Страница 32: ...Outdoor Units MLCAC UTSM 2011 02 30 Outdoor Units 9 Field Wiring PAC366FC I PAC486FC I PAC606FC I ...
Страница 35: ...MLCAC UTSM 2011 02 Features Outdoor Units 33 2 Service Space ...
Страница 37: ...MLCAC UTSM 2011 02 Features Outdoor Units 35 4 Wiring Diagrams PAC247C O ...
Страница 38: ...Features MLCAC UTSM 2011 02 36 Outdoor Units PAC367C O PAC366FC O ...
Страница 39: ...MLCAC UTSM 2011 02 Features Outdoor Units 37 PAC487C O PAC486FC O ...
Страница 40: ...Features MLCAC UTSM 2011 02 38 Outdoor Units PAC606FC O ...