After the pilot holes have been drilled, use four (4)
5
16
˝ x 3˝ lag bolts and four (4) flat washers to
mount the UNI-GB to the wood studs.
Use a ½˝ socket and socket wrench to finish this step.
Socket
Lag Bolt and Square Washer
UNI-GB
Step 5
Once the mounting points have been marked, use a
¼˝ drill bit and portable drill to drill the pilot holes.
Drill
Marking
Step 4
Mark the four (4) mounting slots you are using on
the outside edges of the UNI-GB where you will drill
the drywall.
The mounting slots are for attaching M6 drywall
anchors.
®
Remove the UNI-GB.
¯
Drill the drywall using a 3/8” drill bit where you made
the marks.
Step 1
M6 drywall anchor
Dry Wall Installation
Front view of UNI-GB
Insert and lightly hammer in four (4) M6 drywall
anchors into the drilled holes (see drawing).
®
Use a Phillips screwdriver to tighten each drywall
anchor until the legs have completely compressed
against the back of the wall.
Do not overtighten the drywall anchor.
¯
Remove the drywall anchor screws and set them
aside.
°
Return the UNI-GB to its original position on the
wall so that the mounting slots align with the
drywall anchor sleeves.
±
Insert the drywall anchor screws into the mounting
slots and a drywall anchor sleeve.
²
Use a #2 Phillips screwdriver to tighten each
drywall anchor screw until it is snug.