background image

TECHNICAL SPECIFICATION

Dimensions: 

   595x240x520mm

Weight:    10.7kg

Power 

supply: 

   230V 

~

Power 

consumption: 

  2.5kW

Prem-i-Air Appliances Ltd., Lancots Lane, Sutton,  St. Helens, Merseyside, WA9 3EX

Website: www.prem-i-air.com

Model Number

EH1846

Item

Symbol

Value

Unit

Heat Output

Nominal Heat Output

P

nom

1,657

kW

Minimum Heat Output

(Indicitive)

P

min

0

kW

Maximum Continuous Heat 

Output

P

max,c

2,276

kW

Auxiliary electricity Consumption 

At nominal heat output

el

max

N/A

kW

At minimum heat output

el

min

N/A

kW

At standby mode

el

sb

N/A

kW

Type of heat input, for electric storage local space heaters only (single select)

manual heat charge control, with integrated thermostat

No

manual heat charge control with room and/or outdoor temperature feedback

No

electronic heat charge control with room and/or outdoor temperature feedback

No

fan assisted heat output

No

Type of heat output/room temperature control (single select)

single stage heat output and no room temperature control

No

Two or more manual stages, no room temperature control

No

with mechanic thermostat room temperature control

Yes

with electronic room temperature control

No

electronic room temperature control plus day timer

No

electronic room temperature control plus week timer

No

Other control options (multiple selections possible)

room temperature control, with presence detection

No

room temperature control, with open window detection

No

with distance control option

No

with adaptive start control

No

with working time limitation

No

with black bulb sensor

No

Contact Details

Prem-i-Air Appliances Ltd, Lancots Lane, St Helens, WA9 3EX

Содержание EH1846

Страница 1: ...or User Manual Please Retain for Future Reference This Product is Only Suitable for Well Insulated Spaces or Occasional Use With 3 Heat Settings Adjustable Temperature with Frost Protection Setting Safety Tip Over Switch and 24 Hour Timer ...

Страница 2: ...or should not be covered For indoor use only Do not use in bathrooms wet rooms or other damp locations Do not use this product with an extension lead Not intended for use in Boats Caravans or other similar locations Please allow for a 50 cm safe area around the top and sides Do not place the mains lead beneath a carpet or rug Please ensure the radiator is not positioned below a socket outlet Do no...

Страница 3: ... setting turn the thermostat clockwise until it reaches its furthest point Allow the room to heat up to the required temperature and then rotate the thermostat anti clockwise until you hear the radiator click off Leaving the thermostat in this position will maintain the temperature at this level The unit can work as a frost protection radiator to do so turn the thermostat fully anti clockwise to t...

Страница 4: ...cian at least once every 10 years or at every change of occupancy For office and retail premises and buildings such as village halls the wiring must be inspected at least once every 5 years It is recommended that all buildings be fitted with smoke alarms it is mandatory for new buildings OPERATING COSTS At time of going to press the average cost of electricity is 0 145 per unit kilowatt hour The a...

Страница 5: ... room and or outdoor temperature feedback No electronic heat charge control with room and or outdoor temperature feedback No fan assisted heat output No Type of heat output room temperature control single select single stage heat output and no room temperature control No Two or more manual stages no room temperature control No with mechanic thermostat room temperature control Yes with electronic r...

Отзывы: