INSTALLATION 

It is very important that the tubular heater is mounted horizontally to a wall at low-
level. Do not mount below a socket outlet. Any shelving above the heater must be 
at a distance of no less than 200mm. Air should be allowed to circulate freely 
around the heater in order to prevent overheating.  

THE TUBULAR HEATER MUST NOT BE COVERED.

 

The fixing brackets should be mounted accordingly to the heater length at a 
distance to adequately support the Heater.  
Screw the two bottom halves of the brackets to the wall. Place the Tubular Heater 
on the brackets. Fasten the top brackets over the tube. DO NOT SWITCH ON 
THE HEATER UNTIL AFTER IT HAS BEEN SECURED. 

 

PAT TESTING 

When  used  in  a  workplace,  this  product  should  be  safety-tested  yearly  by  a 
qualified electrician (PAT Tested). We recommend that it is PAT tested regularly 
when used in a domestic environment. 
 

GENERAL SAFETY REQUIREMENTS 

Domestic wiring must be tested periodically by a qualified electrician at least once 
every 10 years or at every change of occupancy. 

For office and retail premises, and buildings such as village halls, the wiring must 
be inspected at least once every 5 years. 
It is recommended that all buildings be fitted with smoke alarms (it is mandatory for 
new buildings). 
 

ELECTRICAL 

The electrical installation of this Tubular Heater must be carried out by a competent 
electrician and be in accordance with the current I.E.E. Regulations for Electrical 
Equipment in Buildings. The Tubular Heater is suitable for operation on a 50Hz AC 
supply voltage as shown on the identity label. Before connecting the heater check 
that  the  supply  voltage  is  the  same  as  stated  on  the  identity  label. 

DO  NOT 

DIRECTLY EXPOSE TO WATER 

 
 

THIS DEVICE IS NON-USER SERVICEABLE 

Should difficulty be experienced with this heater, consult a qualified electrician. 

 

MAINTENANCE 

Before  cleaning,  turn  the  heater  off,  and  disconnect  from  the  mains  supply.  The 
heater may then be cleaned using a damp cloth with a drop of washing-up liquid to 
remove any dust or dirt from the case. Do no use stronger detergents or solvents 
as these may damage the plastic. 

Содержание EH1712

Страница 1: ...1 EH1712 EH1714 EH1716 EH1718 TUBULAR HEATER ...

Страница 2: ...ithout supervision Do not cover For indoor use only Do not use in bathrooms Do not use in wet or damp locations Do not place the mains lead beneath a carpet or rug Do not use the heater in locations where paint petrol or other flammable liquids are used or stored Please ensure heater is switched off when not in use also unplug before assembly or disassembling parts Please avoid the use of an exten...

Страница 3: ...fied electrician at least once every 10 years or at every change of occupancy For office and retail premises and buildings such as village halls the wiring must be inspected at least once every 5 years It is recommended that all buildings be fitted with smoke alarms it is mandatory for new buildings ELECTRICAL The electrical installation of this Tubular Heater must be carried out by a competent el...

Страница 4: ...w wire to the terminal labelled with the earth symbol or E Make sure that the cord grip is positioned correctly over the outer sheath of the cable and it fully tightened SAFETY Due to the high surface temperature of these heaters we strongly recommend the use of our safety guards whenever the devices are situated below 2m from the floor or where Animals Children or Flammable objects such as clothi...

Страница 5: ...aterials and workmanship for a period of one year Should this unit be operated under conditions other than those recommended at voltages other than the voltage indicated on the unit or any attempts made to service or modify the unit then the warranty will be rendered void The product you buy may sometimes differ slightly from illustrations This warranty is in addition to and does not affect your s...