INSTALLATION 

 

The EH1688  must  be permanently fixed to a wall, door frame or ceiling and 
permanently  connected to the mains supply by a qualified electrician  to current 
approved wiring regulations.  The unit can be fixed using bolts through the main 
holes or by four smaller screws on either side of the main holes. In any situation 
the unit needs to be installed in the correct way with the securing screws firmly in 
place. 
To begin draw a horizontal line on the wall approx. 400mm long and mark the centre 
point. Mark 2 points 180.5mm either side of the centre point and then two points 
30mm either side of the two main points. Drill  either two holes either side of the 
main fixing points or two holes on the main points then insert the correct wall plugs 
or bolts. 
The bracket can now be firmly fixed to the wall/ceiling. 

 

Once the bracket is correctly fitted to the wall or ceiling the heather can be slotted 
onto the bracket and the bolts tightened into place. The 2 securing screws should 
be fitted to ensure the unit cannot be accidentally removed or knocked off.  
 
The unit is supplied with a 3 function remote control, this will require the fitting of 2 
AAA batteries for correct operation.

 

 

 

 

Securing Screw 

Содержание EH1688

Страница 1: ...1 EH1688 Over Door Heater Fan Chauffage de Porte Ventilateur ...

Страница 2: ... that curtains are at least 900mm 3 from the top of the heater Leave a gap of at least 200mm 8 at the sides of the heater Do not cover This symbol shown on the casing of the heater means that the heater should not be covered For indoor use only Do not use in bathrooms or in wet or damp locations Do not place the mains lead beneath a carpet or rug Do not install immediately below a socket outlet Do...

Страница 3: ...tre point Mark 2 points 180 5mm either side of the centre point and then two points 30mm either side of the two main points Drill either two holes either side of the main fixing points or two holes on the main points then insert the correct wall plugs or bolts The bracket can now be firmly fixed to the wall ceiling Once the bracket is correctly fitted to the wall or ceiling the heather can be slot...

Страница 4: ... at least once every 5 years It is recommended that all buildings be fitted with smoke alarms it is mandatory for new buildings OPERATION Switch the unit on at the supply socket that will have been installed by the qualified electrician fitting the unit The unit can be operated via the control panel or by the supplied remote control Press the ON OFF button on the remote control or on the main pane...

Страница 5: ...amage the case finish FAULT FINDING The EH1688 has an overheat protection switch which disconnects the power if the element gets too hot The usual reason for this is because the air flow has been obstructed or the grilles have been blocked If the heater ceases to operate leave it for 20 minutes to cool down then check that the grilles are not being obstructed Switch back on and check that the unit...

Страница 6: ...ions other than those recommended at voltages other than the voltage indicated on the unit or any attempts made to service or modify the unit then the warranty will be rendered void The product you buy may sometimes differ slightly from illustrations This warranty is in addition to and does not affect your statutory rights If you have any problems with this product please call our Help Desk on 084...