pressing once will turn the fan on and again will turn it off. 
The heater will now operate at the desired power level till the set 
temperature is reached, the unit will turn off and only turn on again if the 
temperature drops below the set level. 
Do not touch the air output grille when the heater is in operation, because 
it will be hot and may cause burns. 
If the unit is switched off at the panel or the mains supply the settings will 
revert to their default values (Temp = 24°C, Timer = OFF, Heater = OFF). 
Unplug the heater from the mains when not in use. 
 

USING THE TIMER 

To operate the unit on the 24 hour timer the unit must be plugged in and a 
power setting, temperature selected. If the unit is turned off at any time 
the clock will stop and reset. The timer is a simple count down timer and 
will count down from the set time till zero (between 30min and 24 hours) 
when  it  will  turn  off  the  heater.  To  set  the  timer  press  the  Timer         
Button then the Plus or Minus buttons to increase or decrease the required 
operating time in 30 minute steps. The unit will then operate for the set 
time, the timer on the display will count down to zero then turn off,   

 

USING THE THERMOSTAT 

The  thermostat can be used  to regulate the  room temperature  between 
5°C and 37 °C. 
Turn on the heater and set to maximum power and maximum temperature. 
The  heater  will  then  operate  at  maximum  output.  When  the  desired 
temperature is reached reduce the Temperature setting on the display by 
pushing  the  Temp  button  and  then  the  minus  button  till  a  click  can  be 
heard.  The  heater  will  then  switch  on  and  off  to  keep  the  room  at  the 
desired  temperature.  Either  the  "Eco-750W",  "Comfort-1250W"  or  the 
"Super-2000W" setting may be used.   
If the temperature control is set to 5 °C, it will operate as a "frost-stat" and 
switch  the  heater  on  if  the  temperature  drops  below  5°C,  preventing 
damage by frost. 
 

 

Содержание EH1644

Страница 1: ...EH1644 EH1644EU 2kW Convector Heater Remote Control 3 Heat settings Adjustable Digital Thermostat Free standing or wall mounting 24 Hour Digital Timer Safety overload cut out ...

Страница 2: ...rom the end of each side To wall mount Referring to the diagrams below draw two horizontal lines on the wall 330mm apart the lower line more than 50mm from the floor On the upper line drill holes 310mm apart using a 6mm masonry bit and insert a wall plug in each hole On the lower line drill holes 435mm apart centred directly below the upper holes using a 6mm masonry bit and insert a wall plug See ...

Страница 3: ...the round hole in the bracket the oval hole in the bracket locates over the screw that fixes the case together approximately 95mm from the case side at the rear of the unit Hang the heater on the hook brackets using the two 25mm slots The L shaped brackets will now line up with the lower holes in the wall Attach to the wall using the other two 30mm screws See Fig 4 below Fig 3 Fig 4 ...

Страница 4: ... not obstructed Ensure that curtains are at least 900mm from the top of the heater Leave a gap of at least 50mm at the sides of the heater If used free standing do not operate unless the feet are correctly attached Do not place on soft surfaces Do not cover This symbol shown on the casing of the heater means that the heater should not be covered Do not use outdoors Do not use in bathrooms or in we...

Страница 5: ...re that the lead is rated at 10 Amps or more and that it is fully unwound Switch the unit on at the mains socket All the following controls can be operated via the control panel or the remote control Switch the unit on by pushing the On Off button The unit will beep to show it is powered on and ready The display will show the room temperature To set the desired room temperature first press the Tem...

Страница 6: ...till zero between 30min and 24 hours when it will turn off the heater To set the timer press the Timer Button then the Plus or Minus buttons to increase or decrease the required operating time in 30 minute steps The unit will then operate for the set time the timer on the display will count down to zero then turn off USING THE THERMOSTAT The thermostat can be used to regulate the room temperature ...

Страница 7: ...unit is operating normally If not contact an authorised service agent for repair If the unit is turned off at any time the thermostat will reset to 24 C if the room temperature is above this level the unit will not operate Adjust the thermostat to the desired temperature MAINTENANCE Before cleaning turn the heater off and disconnect from the mains supply The heater may then be cleaned using a damp...

Страница 8: ... current 8 7A SERVICE WARRANTY Prem i Air guarantees the product free from defects in materials and workmanship for a period of one year Should this appliance be operated under conditions other than those recommended at voltages other than the voltage indicated on the appliance or any attempts made to service or modify the appliance then the warranty will be rendered void The product you buy may s...

Отзывы: