background image

2837 

Ver. 1 - 04/14 

IMPORTANT 

Installer and Users please note: 

These instructions should be read carefully and left with the user of the product 
for future reference. 

INSTALLATION 

To wall-mount:  

This unit should be mounted at least 60 cm below any ceiling and must have 
30 cm clearance on each side. Flammable items, for example patio umbrellas, 
should be no closer than 150 cm from the front grille.  

When the correct mounting point has been established draw two horizontal lines 
on the wall 90 mm (3½") apart, the lower line more than 1500 mm (5') from the 
floor. Mark a centre line vertically down across both lines (fig.1). 

On the upper line, drill holes 130 mm (approx. 5¼") from the centre line on each 
side, using a 6 mm (¼") masonry bit, and insert a wall plug.  
On the lower line repeat the actions marking and drilling 2 holes and inserting the 
correct wall plugs (fig.2).  

Insert screws into the lower two holes and tighten to 3 mm from the wall (fig.3). 

Hang the heater on the lower screws using the keyhole slots on the back (fig.4). 

Insert  screws  through  the  upper  2  holes  in  the  heater  bracket  and  tighten  fully 
(fig.5&6). 

The  desired  angle  can  be  set  using  the  2  pivot  screws  on  the  bracket.  These 
should be fully tightened and checked before the unit is switched on. 

1.

 

 

 

 

2. 

 

 

Содержание EH1462

Страница 1: ...1 2837 Ver 1 04 14 EH1462 2 3 kW PATIO HEATER CHAUFFAGE DE PATIO 2 3kW ...

Страница 2: ... than 1500 mm 5 from the floor Mark a centre line vertically down across both lines fig 1 On the upper line drill holes 130 mm approx 5 from the centre line on each side using a 6 mm masonry bit and insert a wall plug On the lower line repeat the actions marking and drilling 2 holes and inserting the correct wall plugs fig 2 Insert screws into the lower two holes and tighten to 3 mm from the wall ...

Страница 3: ...3 2837 Ver 1 04 14 3 4 5 6 7 8 ...

Страница 4: ... connected via a Residual Current Device RCD rated at 30 mA or less The heater must be installed where it cannot be touched whilst in a bath or shower This heater must not be connected to a timer or other type or programmable switch a fire hazard exists if the heater is covered when the timer switches it on The fireguard of this appliance is intended to prevent direct access to the heating element...

Страница 5: ...ns off the integrated light H Front Panel Only Turns on and off the 2 heating bars The unit has 3 power modes and off bottom tube 1150 W top tube 1150 W and both tubes 2300 W Press the button gain to turn them all off H1 H2 Remote Control Only independently turns off and on the two heating tubes H1 Bottom H2 Top Eco Panel Remote Control this puts the unit into Eco mode in this position the unit s ...

Страница 6: ...d it must be replaced by the manufacturer or and authorised service centre If the mains plug needs to be replaced proceed as follows Connect the brown wire to the terminal labelled L Connect the blue wire to the terminal labelled N Connect the green yellow wire to the terminal labelled with the earth symbol or E Make sure that the cord grip is positioned correctly over the outer sheath of the cabl...

Страница 7: ...izontales sur le mur distantes l une de l autre de 90mm la ligne du bas devant être tracée à plus de 1500mm du sol Tracez une ligne centrale verticale coupant ces deux traits Fig 1 Sur la ligne du haut percez des trous de chaque côté à 130mm du trait central en utilisant un foret à maçonnerie puis insérez une cheville murale Sur la ligne du bas répétez la même action fig 2 Insérez des vis dans les...

Страница 8: ...8 2837 Ver 1 04 14 3 4 5 6 7 8 ...

Страница 9: ...it provoquer une surchauffe ou un choc électrique et endommager le radiateur S il est utilisé à l extérieur le radiateur doit être branché via un dispositif de courant résiduel calibré à 30mA ou moins Le radiateur doit être installé à un endroit afin qu il ne puisse pas être touché depuis une baignoire ou une douche Le radiateur ne doit pas être connecté à un programmateur ou un commutateur progra...

Страница 10: ...niquement Allume et éteint les 2 tubes chauffants L appareil peut fonctionner selon 3 modes différents le tube du bas 1150W uniquement le tube du haut uniquement 1150W ou les 2 tubes 2300W Appuyez de nouveau sur le bouton pour tous les éteindre o H1 H2 sur la télécommande uniquement allume et éteint indépendamment les deux tubes chauffants H1 pour le tube du bas et H2 pour le tube du haut o Eco Fa...

Страница 11: ...astique A l aide d un pinceau sec 25 mm enlevez la poussière des grilles Si le cordon d alimentation est endommagé il doit être remplacé par un électricien confirmé Procédez comme suit Connectez le câble marron sur le bornier libellé L Connectez le câble bleu sur le bornier libellé N Connectez le câble vert jaune sur le bornier libellé E ou portant le symbole terre Vérifiez que le serre câble est ...

Страница 12: ...Appliances Ltd Lancots Lane Sutton St Helens Merseyside WA9 3EX website www prem i air com GARANTIE Prem I Air garantit ce produit contre tout défaut de fabrication ou de matériaux pendant douze mois Si ce radiateur est utilisé dans des conditions autres que celles recommandées dans cette notice à des tensions autres que celles indiquées sur l appareil la garantie est annulée De même toute tentati...