12
www.pregis.com
52
-
OM216
-
1
Operation
1.
Select the tail position using Tail
Position Switch.
3.
Switch to the right: Coil is completed
with the tail in the top position allow-
ing access for manual taping of the
coil end.
4.
When the coil is complete and wound
to the selected tail position, the Coil
Indicator will start to flash denoting
operator action is required to remove
the coil.
Once the coil is removed, the Coil Indi-
cator will extinguish, and the Coiler
-
lite
is ready for the next coil to be produced.
2.
Switch to left (normal position): Coil
is completed with the tail in the bot-
tom position which keeps the tail in
position until the coil is removed.
Coil production can be stopped at any point during the winding process by pressing the Red
‘
Stop
’
button. This will immediately stop the pack being produced by the Packmaster
™
pro
and will result in a smaller incomplete coil.
This may place the Coiler
-
lite into a temporary
‘
fault
’
mode and the Coil Indicator will start
to flash denoting operator action is required to remove the coil. To exit the
‘
fault
’
mode
remove the coil and press the White
‘
Home
’
Button once. The Coil Indicator extinguishes
and the machine is ready to run again.