8
3.2.1 Exiting Advanced Setup
Pressing the Menu key returns you to the General Operation screen.
Pressing the Play key starts the unit and returns you to the General
Operation screen.
If you don‟t press a key for 60 seconds, the Advanced Setup screen times-
out and the unit returns to the General Operation screen.
3.2.2 Individual Parameters
The following subsections discuss each individual parameter. Some are
changeable, some are not and some are reserved for future enhancements.
3.2.2.1 Version
The version parameter displays the unit‟s software version. It is a view only
parameter.
3.2.2.2 Belt Odo
This is the belt odometer reading in feet. To reset: press (and hold) the
enter key, then press (and hold) the up key for five seconds when the
number line is selected. The odometer reading will display in meters if the
Units are changed to metric. Note: divide meters by 1000 to get kilometers.
3.2.2.3 Test Mode
The „test mode‟ parameter allows the unit to run regardless of the „lost film
sensor‟. Test mode times out after 15 minutes.
3.2.2.4 Temp Low & Temp High
These parameters form the range in which an operator can set the sealer‟s
temperature setpoint, see section 2.2.1 . Both values are expressed as a
percentage of the sealer‟s range; from „full off‟ (0) to „full on‟ (100).
Temp Low can be set from zero to Temp High minus one.
Temp High can be set from Temp Low plus one to 100.