4
2.2.1 Temperature Setting Screen
The Temperature Setting screen is available only
after the entry of a valid password, see section
3.1 . While in the General Operation screen,
pressing the Menu button brings you to the Temperature Setting screen
2
.
Use the arrow keys to increase or decrease the temperature of the seal wire.
The value is a percentage of the allowed temperature range that is set using
the Advanced Setup screen. Temperature Setting screen can be entered
while the unit is running and any changes take effect immediately.
Pressing Up or Down arrow keys, increment or decrement the temperature,
respectively.
Pressing Enter returns to General Operation screen
Pressing Menu takes you to the Inflation Setting screen
Pressing Play toggles the running state of the unit and remains at the
Temperature Setting screen
2.2.1.1 Temperature Setting Timeout
If you don‟t press a key for 60 seconds, Temperature Setting screen times-
out and the unit returns to the General Operation screen.
2.2.1.2 Temperature Test Mode
When test mode is enabled, see 3.2.2.3 Viewing the
Temperature Setting Screen will display the Set
Temperature percentage and the actual temperature of the thin film heater.
2.2.2 Inflation Setting Screen
If the Advanced Setup is not activated then the
Menu button will bring you to the Inflation Setting
screen directly from the General Operation Screen.
When Advanced Setup is activated pressing the Menu button while in the
2
If a valid password has not been entered you are taken to the Inflation Setting screen,
section 2.2.2
TEMPERATURE
50
AIR ADJUSTMENT
50
SET TEMP
50
ACTUAL
122 F